ANTI-RODENT · CABLE FIRE PROTECTION
PROTECT THE CABLE. PROTECT THE PLANT.
RATS BITE CABLES
One bite can cause fire or stop production.
Bitten insulation. Exposed copper.
The risk remains.
30-DAY RODENT TEST
19
BITE MARKS
Uncoated cable
0
BITE MARKS
7034-coated
cable
Same cages. Same 30 days.
Food freely available.
RDSO/SPN/204 Annexure G — NABL lab
Rodent classification: SAFE
ONE COATING. TWO PROTECTIONS.
120 min
FLAME-SPREAD TEST
CBRI — IEC 60332-3-22, Category A
Helps limit flame spread along coated cables.
Tested build: 1.5 mm, directly on the cable.
WORLD FIRST
Intumescent cable coating:
translucent, flexible and anti-rodent.
THE LOSS GOES BEYOND THE CABLE.
Rat bite
Exposed conductor
Electrical fault
Fire / shutdown
Cable fire.
Production at risk.
A cable fault can mean
- Fault-finding
- Cable replacement
- Production loss
- Restart delays
ALREADY PAYING FOR PEST CONTROL?
Protect the cable too.
Pest control reduces rodent activity. 7034 protects the cable. Use both.
PROTECT THE WIRING INSIDE PANELS
Protect panel wiring.
Keep cable identification visible.
Translucent protection.
Helps keep identification visible.
For sound, insulated fixed wiring in panels,
distribution boards and junction boxes.
Isolate before application. Follow the approved
method. Keep contacts, terminals and moving
parts clear.
FIRE-COATED. RODENT-PROTECTED?
Keep the fire coat. Add 7034.
Indoor cable routes.
Add 7034 over the fire coat.
Fire coatings may lack rodent protection. Add
7034 over sound, firmly adhered, compatible
coatings on indoor fixed cable runs.
Check adhesion and compatibility on a trial
section. Use the Stanvac-approved system.
0.5 mm recommended overcoat: application build only.
The 1.5 mm direct-to-cable test ratings do not automatically apply to combined systems.
Start with one critical panel or cable route.
Get the coating specification and price.
WHERE SHOULD YOU START?
Start where cable failure threatens production, essential services or people.
FOOD, PHARMA & STORAGE
Protect processing, packing and refrigeration.
SN
INDUSTRY
PRIORITY CABLE LOCATIONS
01
Food processing,
dairy & beverage
Production and packing trays; MCC wiring; chiller
corridors.
02
Grain, sugar, rice
& feed mills
Conveyor runs; silo wiring; mill panels.
03
Cold storage
& warehousing
Compressor rooms; racking routes; dock panels.
04
Pharmaceutical
& FMCG
Service shafts; ceiling voids; AHU and utility wiring.
BUILDINGS & TRANSPORT
Protect essential services for patients, guests and passengers.
SN
INDUSTRY
PRIORITY CABLE LOCATIONS
05
Hospitals & healthcare
Risers; ward ceiling routes; OT and diagnostic
wiring.
06
Hotels, malls
& cinemas
Kitchen service routes; shafts; basement trays.
07
High-rise commercial
Risers; basement trays; floor distribution wiring.
08
Railways, metro
& airports
Signalling routes; tunnels; station voids; cargo
sheds.
POWER, DATA & HEAVY INDUSTRY
One cable fault can disrupt a larger system.
SN
INDUSTRY
PRIORITY CABLE LOCATIONS
09
Data centres
& telecom
Under-floor routes; rack supply trays; UPS rooms.
10
Substations &
cable basements
Trenches; basement runs; control and relay wiring.
11
Solar plants &
battery storage
Low-level DC cables; combiner wiring; inverter
rooms.
12
Refineries, petrochemical
& fertiliser
Instrumentation trays; junction-box wiring; sleeper
crossings.
13
Steel, cement, mines
& heavy industry
MCC wiring; control cables; machine and starter
panels.
COAT THE CABLE BEFORE
THE BITE BECOMES A FIRE.
GET A COATING RECOMMENDATION
AND QUOTATION.
Send panel, tray or cable-basement photos.
Ask for the specification, test reports and price.
Keeping People Safe. Keeping Plants Running.