MECHANICAL SOLUTIONS
CERAMIC WEAR PROTECTION
Anti-abrasion and anti-erosion coatings for steel mills
FOR SELECTED DUTIES BELOW 120°C
01 CERAMIC PRIMER
1180 NMB Ceramic Coat
FLEXIBLE PRIMER · ST3 GRINDING
Nano Molecular Bonding (NMB) anchors 1180 to
ST3-ground steel without abrasive blasting for
specified applications. The flexible ceramic primer
resists brittle cracking and peeling, helping keep
the full system bonded.
02 CERAMIC WEAR LAYER
731 ER XTREAM
NANO ZIRCONIUM WEAR RESISTANCE
This fibre-reinforced putty uniquely uses hard
nano zirconium for substantially better abrasion
and erosion resistance than conventional
ceramic-bead or standard zirconium coatings.
Higher coverage per kg reduces coating
consumption.
STEEL MILLS
Cooling water, abrasive slurry and wet material handling

Illustrative problem and after views

AFTERWET GRIT SCOURS GROOVES INTO THE SLURRY
PUMP VOLUTE AND CUTWATER.
01
Abrasive Slurry Pump Casings
Steelworks slurry pump casings, volutes and
cutwaters in approved wet service.
1180 primes the prepared casting. 731 ER XTREAM
rebuilds local wear to the specified flow profile.
Slow wet abrasion and help extend the interval
between wet-end repairs.

AFTERABRASIVE WASTE CUTS CHANNELS INTO THE FLUME
FLOOR AND SIDEWALL.
02
Wastewater Flume Wear Zones
Scoured flow surfaces in approved steel mill
wastewater flumes.
1180 primes the compatible prepared lining. 731 ER
XTREAM fills local grooves to restore the channel
profile.
Help keep solids moving through the flume and
reduce repeat lining repairs.

AFTERSCALE GRIT SCOURS OUT GROUT AND EXPOSES TILE
EDGES IN THE SLUICE.
03
Scale-Water Sluice Tile Joints
Wear at tiles and lining transitions in downstream
rolling-mill sluices carrying cooled scale water.
1180 primes the approved prepared surface. 731 ER
XTREAM fills recessed joints and restores a flush
transition to sound tiles.
Reduce places where grit can lodge and keep sound
lining in service longer.

AFTERPITTING AND EROSION EAT INTO THE INLET LIP OF
THE COOLING-WATER PUMP.
04
Caster Cooling-Water Pump Inlets
Suction covers and eroded inlet surfaces on casting
cooling-water pumps.
1180 primes prepared metal. 731 ER XTREAM
rebuilds worn areas to the specified inlet contour.
Help preserve inlet geometry and extend service
between pump overhauls.

AFTERRECYCLED PROCESS WATER PITS THE WALL INSIDE
THE STRAINER HOUSING.
05
Recycled-Water Strainer
Housings
Erosion and corrosion on the internal flow surfaces of
steel mill recycled-water strainer housings.
1180 primes the prepared metal. 731 ER XTREAM
rebuilds local pitting while preserving the basket
seating and seal profiles.
Protect internal flow surfaces and help extend
housing service life.
Confirm the peak metal temperature, substrate condition and particle or slurry duty before specification. Use the approved
wet-service temperature and chemistry for immersed parts.
STANVAC CHEMICALS INDIA LTD.