MECHANICAL SOLUTIONS

CERAMIC WEAR PROTECTION

Anti-abrasion and anti-erosion coatings for thermal power plants

FOR SELECTED DUTIES BELOW 120°C

01  CERAMIC PRIMER

1180 NMB Ceramic Coat

FLEXIBLE PRIMER · ST3 GRINDING

Nano Molecular Bonding (NMB) anchors 1180 to
ST3-ground steel without abrasive blasting for
specified applications. The flexible ceramic primer
resists brittle cracking and peeling, helping keep
the full system bonded.

02  CERAMIC WEAR LAYER

731 ER XTREAM

NANO ZIRCONIUM WEAR RESISTANCE

This fibre-reinforced putty uniquely uses hard
nano zirconium for substantially better abrasion
and erosion resistance than conventional
ceramic-bead or standard zirconium coatings.
Higher coverage per kg reduces coating
consumption.

THERMAL POWER PLANTS

Coal handling, fuel conveying, fly ash and wet FGD

Thermal power plant with cooling towers, boiler house, chimney and coal conveyor

Illustrative problem and after views

Fast-moving coal dust scours the outer curve of the bend.Illustrative after view: the worn area rebuilt and protected with 1180 + 731 ER XTREAMAFTER

FAST-MOVING COAL DUST SCOURS THE OUTER
CURVE OF THE BEND.

01

Pulverised-Fuel Pipe Bends

APPLICATION

Internal wear zones in pulverised-fuel bends and
direction changes.

TECHNOLOGY

1180 primes the prepared metal. 731 ER XTREAM
lines the outer radius, where the coal stream strikes
the wall.

CUSTOMER GAIN

Help prevent local wall loss and reduce repeat elbow
repairs during outages.

Ash scours the inside wall where the transfer pipe branches.Illustrative after view: the worn area rebuilt and protected with 1180 + 731 ER XTREAMAFTER

ASH SCOURS THE INSIDE WALL WHERE THE
TRANSFER PIPE BRANCHES.

02

Ash-Transfer Pipe Branches

APPLICATION

Wear faces inside ash-transfer forks and Y-junctions.

TECHNOLOGY

1180 primes the sound metal. The nano zirconium
layer of 731 ER XTREAM protects the wall where ash
changes direction.

CUSTOMER GAIN

Reduce repeated wear-through at the junction and
preserve the flow path.

Fly ash scours the fan casing and wears away the discharge edge.Illustrative after view: the worn area rebuilt and protected with 1180 + 731 ER XTREAMAFTER

FLY ASH SCOURS THE FAN CASING AND WEARS
AWAY THE DISCHARGE EDGE.

03

Fly-Ash Transfer Fan Casings

APPLICATION

Stationary casing walls and discharge wear zones in
dry fly-ash transfer fans.

TECHNOLOGY

1180 primes the casing. Fibre-reinforced 731 ER
XTREAM restores worn areas and forms a renewable
wear layer.

CUSTOMER GAIN

Protect the fan housing and reduce casing repairs
between planned outages.

Abrasive ash slurry pits the volute and erodes the cutwater.Illustrative after view: the worn area rebuilt and protected with 1180 + 731 ER XTREAMAFTER

ABRASIVE ASH SLURRY PITS THE VOLUTE AND
ERODES THE CUTWATER.

04

Fly-Ash Slurry Pump Casings

APPLICATION

Wet-end casing, volute and cutwater in approved
fly-ash slurry duties.

TECHNOLOGY

1180 primes prepared metal. 731 ER XTREAM
rebuilds local wear and protects the specified profile.

CUSTOMER GAIN

Preserve casing geometry and help extend the
interval between wet-end repairs.

Limestone slurry scours the bore and wears the lower pipe wall.Illustrative after view: the worn area rebuilt and protected with 1180 + 731 ER XTREAMAFTER

LIMESTONE SLURRY SCOURS THE BORE AND WEARS
THE LOWER PIPE WALL.

05

FGD Slurry Pipe Spools

APPLICATION

Removable slurry spools in wet flue-gas
desulphurisation systems.

TECHNOLOGY

1180 provides the ceramic primer. 731 ER XTREAM
protects the bore in approved slurry chemistry and
immersion conditions.

CUSTOMER GAIN

Slow bore wear and extend the usable life of
replaceable spool pieces.

Sliding coal scours the feed box floor and sidewalls.Illustrative after view: the worn area rebuilt and protected with 1180 + 731 ER XTREAMAFTER

SLIDING COAL SCOURS THE FEED BOX FLOOR AND
SIDEWALLS.

06

Coal Feed Boxes

APPLICATION

Fine-coal sliding zones in feed boxes and their
discharge lips.

TECHNOLOGY

1180 primes the prepared steel. 731 ER XTREAM
protects the floor and sidewalls along the coal flow
path.

CUSTOMER GAIN

Slow steel loss and reduce feed-box rebuilds or
replacements.

Confirm the peak metal temperature, substrate condition and particle or slurry duty before specification. Use the approved
wet-service temperature and chemistry for immersed parts.

STANVAC CHEMICALS INDIA LTD.