CPWD ELECTRICAL SPECIFICATIONS 2023
Part I — Internal | Fire barriers, sealing + essential electrical circuits
For projects adopting CPWD specifications · confirm applicable local building requirements

CPWD BUILDINGS.
SAFE ESCAPE.
SEAL OPENINGS.
PROTECT CRITICAL CABLES.
Government guidance.
Stanvac technology. Your gain.
6 APPLICATIONS / WALLS · FLOORS · FIRE PUMPS · SMOKE CONTROL · ALARMS
01
CABLE OPENINGS THROUGH WALLS

A fire-rated wall is weakened by an open cable gap.
The electrical inspection provisions include fire barriers and
sealing to restrict fire spread.
STANVAC SOLUTION
FM 71 + FB250 HYBRID COMBO
Mortar strength + mineral-wool boards: load-bearing safety
+ easier cable retrofitting, with the specified supports and
tested assembly.
YOUR GAIN
Contain fire and smoke at the opening. Ease cable
retrofits.
Select the tested assembly for the wall, cables and required rating. Confirm the
local fire-authority and project requirements.
02
FLOOR + SHAFT CROSSINGS

An open shaft can carry fire from floor to floor.
Apply the specified fire barriers and seals at required
fire-compartment crossings.
STANVAC SOLUTION
FM 71 + FB250 HYBRID COMBO
A matching 2-hour tested hybrid brings mortar strength
together with mineral-wool boards for easier future cable
additions.
YOUR GAIN
Protect floor separation. Make future re-entry
manageable.
The floor rating, permitted services and supports govern the seal detail. Restore
the tested arrangement after cable changes.
03
FIRE-PUMP + PRESSURISATION FEEDS

A pump or pressurisation fan needs a surviving
power feed.
CPWD 2023 · 3.1.7 · TABLE (i), (ii)
Specifies 950°C / 180-minute FS cables with the stated fire,
water and shock duty for these services.
STANVAC SOLUTION
EC 43 SURVIVAL
Submit a matching complete-system proposal. Stanvac
reports 180 min at 950°C to IS 17505-1 for its tested cable
system.
YOUR GAIN
Help essential fire-response equipment keep
working.
Coating is not an automatic substitute for specified FS cables. Demonstrate
every required fire, water and shock test condition.
04
SMOKE-VENTING CONTROL CIRCUITS

Failed control cables can prevent smoke extraction.
CPWD 2023 · 3.1.7 · TABLE (iii)
Smoke-venting circuits, including damper and actuator
services, are specified for 950°C / 60 minutes.
STANVAC SOLUTION
EC 43 SURVIVAL
Assess compatible cables for continuous route protection.
Submit the tested cable type, coating build and
circuit-performance evidence.
YOUR GAIN
Help smoke-control systems remain available for
evacuation.
Obtain design approval for the full circuit. Protect connections and supports;
preserve cable capacity, movement and equipment ventilation.
05
EXIT SIGNS + EMERGENCY LIGHTING

Dark escape routes make evacuation harder.
CPWD 2023 · 3.1.7 · TABLE (vi), (vii)
Specifies 950°C / 120 minutes for exit-sign and
emergency-lighting cable duties.
STANVAC SOLUTION
EC 43 SURVIVAL
Propose full-route protection on an accepted cable system.
Match the specified temperature, duration and installation
conditions.
YOUR GAIN
Help keep escape routes illuminated during fire.
Emergency power, circuit segregation and required FS cable specification remain
essential. Replace defective cables before treatment.
06
FIRE-ALARM CABLE ROUTES

A broken alarm circuit can delay evacuation.
CPWD 2023 · 3.1.7 · TABLE (viii)
Specifies 650°C / 60 minutes for conventional and
intelligent-addressable fire-alarm cable duties.
STANVAC SOLUTION
EC 43 SURVIVAL
Additional cable-route protection, subject to the alarm
designer’s approval and matching system evidence.
YOUR GAIN
Support reliable alarm signalling when it matters.
Do not coat sensing cable, detectors or sampling holes. Retain the prescribed
alarm system, cable specification and standby power.
THE TEST MUST MATCH THE PROTECTION YOU NEED.
2 HOURS
FM 71 + FB250
HYBRID COMBO
Penetration firestop
IS 12458
Match the tested assembly
180 MIN
EC 43 SURVIVAL
Circuit survival at 950°C
IS 17505-1
Match all required test conditions
240 MIN
EC 43 SURVIVAL
Circuit survival at 750°C
IEC 60331-21
4-core × 70 mm² XLPE / 1.6 mm
Performance figures are reported by Stanvac for specific tested systems. Obtain the matching test report and installation detail. Flame-spread resistance,
circuit survival and penetration fire resistance are different performances.
START WITH YOUR MOST VULNERABLE AREA.
Send cable-route, panel and opening photos.
Ask Stanvac for a site survey, system specification and offer.
GOVERNMENT SOURCE CPWD General Specifications for Electrical Works, Part I — Internal, 2023: Annex A-6.4(d) and §3.1.7. Technical guidance for projects adopting
these specifications; not a universal statutory mandate.
PRODUCT DETAILS EC 43 / EC 7034 · FM 71 + FB250 HYBRID COMBO · 931B STRIPPEX
Confirm applicable building standards, local bye-laws, fire-authority conditions and the contract specification. A coating proposal does not automatically replace specified FS
cables. Match required fire, water and mechanical-shock conditions.
Selected sales applications, not a complete fire-safety checklist. Stanvac proposals do not imply government endorsement or whole-facility compliance. AI sector and