Stanvac Chemicals India Ltd.

The Stanvac Electrical Advantage


Electrical Maintenance Solutions 2026 — 34 Products, Five Categories

Stanvac Electrical — Why Buy? Every product, two answers — A) Best-in-World Technology · B) Unique Customer Gain.

Also delivered turnkey: one vendor, one warranty, outcomes guaranteed.

Systems: Cable Survival™ · Panel Fire Immunity™ · Firestop Barrier™ · Dielectric Flooring™ · Switchyard/HV™ · Transformer Guard™ · Battery/UPS™

SHP = built-in dust & water repellency. Dust and moisture cause leakage, arcing, sparking, overheating, pitting and fire. SHP repels both — so none can start.
PASSIVE FIRE PROTECTION

Stanvac PCO — Panels · Cables · Openings: the world’s only complete electrical fire defence.

Fire chain: spark in panel → small wire → cable highway → openings. Every link defended.

Legal stakes: a fire death is a personal criminal offence for the owner, director and manager — and uninsurable (BNS 2023 · OSH Code 2020).

Cable entries and panel gaps sealed against fire and pests.
Cable entries and panel gaps sealed against fire and pests.
1. FIREX FBS 73 — Fire Sealant (Putty Stick)
Why seal panel gaps and cable entries with FBS 73?
A) Best-in-World Technology: India’s first oxygen-limiting panel sealant — sparks and short circuits never grow into large fires.
B) Unique Customer Gain: Stops small faults becoming costly fires; blocks dust, moisture, insects and rodents.
An unprotected panel ablaze — the fire DC 52 prevents.
An unprotected panel ablaze — the fire DC 52 prevents.
2. FIREX DC 52 — Intumescent Fire-Suppression Paint
Why coat electrical panels with DC 52 fire-suppression paint?
A) Best-in-World Technology: India’s first fire-barrier panel coating — stops panel paint feeding the fire and suppresses ignition at source.
B) Unique Customer Gain: Panel fires cannot spread — no equipment loss, no downtime, no injury.
Fire-charred cables; coated circuits stay alive.
Fire-charred cables; coated circuits stay alive.
3A. FIREX EC 43 — Longest-Duration Circuit Survival
Why coat critical-circuit cables with the EC 43 Fire Survival Kit?
A) Best-in-World Technology: The world’s only coating that keeps critical circuits alive in a fire — and never feeds it. Certified to IEC 60331-21 and IS 17505-1.
B) Unique Customer Gain: No circuit failures or shutdowns during or after a fire — and no post-fire cable replacement, which usually costs more than the fire itself.
Cable highways whose sheathing won’t carry fire.
Cable highways whose sheathing won’t carry fire.
3B. FIREX EC 43 — Longest-Duration Propagation Prevention
Why coat general cabling with EC 43 to prevent fire propagation?
A) Best-in-World Technology: The world’s longest flame-propagation protection — IEC 60332-3 for 240 minutes at just 1.6 mm. CBRI-certified, low smoke.
B) Unique Customer Gain: The sheathing cannot feed a fire — no fuel, no fire, no losses. A local fault never goes plant-wide.
Server-room cables alight; 7034 denies the fuel.
Server-room cables alight; 7034 denies the fuel.
4. FIREX 7034 — Translucent, Flexible Intumescent Cable Coating
Why coat small-diameter power, networking and instrumentation cables — the first to catch fire — with 7034?
A) Best-in-World Technology: The world’s first intumescent coating that is both translucent and flexible — passes IEC 60332-3 for 120 minutes.
B) Unique Customer Gain: Takes away the cable sheathing as fuel — no fuel, no fire. Stops ignition from arcs, sparks and hot joints.
A wall opening fire-stopped with castable mortar.
A wall opening fire-stopped with castable mortar.
5. FIREX FM 71 — Castable Fire-Stop Mortar
Why use FM 71 castable fire-stop mortar for wall and floor openings?
A) Best-in-World Technology: The world’s most advanced fire-stop mortar — a two-hour rating at just 75 mm, with a 20-year life.
Two ways to fit: Standalone 75 mm / 2 hr — India’s lightest and most economical; or hybrid 50 mm FM 71 + 50 mm FB 250 — the strengths of both.
B) Unique Customer Gain: Stops fire and smoke spreading between rooms and floors — a faster, lighter retrofit.
Re-enterable mineral-wool seal around cable penetrations.
Re-enterable mineral-wool seal around cable penetrations.
6. FIREX FB 250 — Mineral-Wool Fire-Stop Barrier
Why install the FB 250 mineral-wool barrier around cable penetrations?
A) Best-in-World Technology: Mineral-wool fire barrier certified up to four hours — and re-enterable for future cable changes.
B) Unique Customer Gain: Add or change cables anytime without breaking the fire seal. With FM 71, you get sealing plus load-bearing.
CLEANING, INSULATION AND PROTECTION
Cleaning a live, energised panel without shutdown.
Cleaning a live, energised panel without shutdown.
7. #901 Easy Clean CO₂ 360 SHP NF — On-Line Cleaner
Why use #901 on energised panels surrounded by plastics and sensitive surfaces?
A) Best-in-World Technology: The world’s only non-flammable on-line cleaner — clean and re-energise in minutes; fully safe on plastics.
SHP edge — repels dust & water: Repels the dust and moisture that cause leakage, arcing and overheating — contacts stay fault-free for months.
B) Unique Customer Gain: Clean live equipment without shutdown — no production loss, months of protection.
Switches, relays and contactors kept fault-free.
Switches, relays and contactors kept fault-free.
8. #415 Off-Line Contact Cleaner CO₂ 360 SHP
Why pick #415 off-line contact cleaner for switches, relays and contactors?
A) Best-in-World Technology: The world’s best plastic-safe, CFC-free off-line contact cleaner — fast-drying, zero residue.
SHP edge — repels dust & water: Dust and moisture cause leakage and pitting on contacts. SHP repels both — switching stays clean and reliable.
B) Unique Customer Gain: Reliable switches, relays and contactors — fewer faults, longer gaps between cleanings.
Spraying a circuit board clean in an occupied room.
Spraying a circuit board clean in an occupied room.
9. #8376 Electronic Component Cleaner CO₂ 360 SHP
Why use #8376 component cleaner inside closed, air-conditioned control rooms?
A) Best-in-World Technology: India’s only low-odour, plastic-safe, residue-free electronic cleaner — safe in closed AC rooms.
SHP edge — repels dust & water: Repels the dust and moisture that cause leakage and tracking on boards — protected for months.
B) Unique Customer Gain: Clean sensitive electronics in occupied rooms — no odour, no residue, lasting protection.
Deep-cleaning energised gear without flashover risk.
Deep-cleaning energised gear without flashover risk.
10. #8060 Safety Solvent CO₂ 360 NF — Heavy-Duty Cleaner
Why choose #8060 heavy-duty solvent for cleaning energised electrical systems?
A) Best-in-World Technology: Non-flammable on-line dielectric cleaner — removes grease and oil, prevents flashovers, leaves no residue.
B) Unique Customer Gain: Deep-clean energised systems — no shutdown, no fire risk.
Moisture driven out of motors and bus bars.
Moisture driven out of motors and bus bars.
11. #8070 Electrical 88 CO₂ SHP — Moisture Displacer
Why apply #8070 before and through the monsoon?
A) Best-in-World Technology: Heavier-than-water formula drives out moisture and restores insulation resistance (IR) in motors and bus bars.
SHP edge — repels dust & water: Repels the water and dust that cause arcing on bus bars — no sparking, no flashover, all season.
B) Unique Customer Gain: Get through the monsoon without flashovers — motors and bus bars stay dry for six months.
Flashover carbon lifted from copper contacts.
Flashover carbon lifted from copper contacts.
12. #8480 Carbon Cleaner — Thick-Film Foam Gel
Why use #8480 for thick flashover carbon and bonded deposits?
A) Best-in-World Technology: India’s only thick-film foam gel — lifts heavy carbon without abrasion; safe on silver and copper.
B) Unique Customer Gain: Removes stubborn carbon without scratching — restores contacts, extends commutator and contactor life.
Motor end-turns coated in-situ against moisture.
Motor end-turns coated in-situ against moisture.
13. #6084 Red Insulating Varnish SHP (Class F)
Why open the end covers and spray fast-drying #6084 into motor windings in-situ?
A) Best-in-World Technology: The world’s only fast-drying SHP insulating varnish — coats winding end-turns in place; resists arcing and tracking.
SHP edge — repels dust & water: Repels the moisture, dust and chemical fumes that enter through ventilation ports and attack windings — the root cause.
B) Unique Customer Gain: Prevents winding damage — no IR collapse, no burnout — extends motor life and avoids costly rewinds.
Insulators, CTs and PTs guarded against tracking.
Insulators, CTs and PTs guarded against tracking.
14. #Z906 Provar Anti-Track SHP (Class H)
Why coat inside-panel insulators, CTs and PTs with Z906 anti-track?
A) Best-in-World Technology: The world’s only SHP anti-track coating for insulators, CTs and PTs — high dielectric strength, restores IR.
SHP edge — repels dust & water: Repels the dust and moisture that cause surface tracking — the root cause.
B) Unique Customer Gain: No tracking, no flashovers, no panel breakdowns, no fire — panels and metering stay reliable.
Aged cable joints given a new protective skin.
Aged cable joints given a new protective skin.
15. #1465(A) Flexiguard SHP — Cable Joint & Sheathing Sealer
Why seal cable joints and cracked, aged sheathing with Flexiguard?
A) Best-in-World Technology: The world’s only flexible, fire-retardant SHP coating — bonds strongly to PVC, rubber and metal.
SHP edge — repels dust & water: Repels the moisture and dust that make aged joints leak and break down — so failures cannot start.
B) Unique Customer Gain: Old cables and joints get a new protective skin — failures prevented, cable life extended.
Bus-bar joints insulated, locked and colour-coded.
Bus-bar joints insulated, locked and colour-coded.
16. #Z931(A) Strippex SHP — Joint & Bus-Bar Insulation (2 kV / 11 kV)
Why coat motor-cable, busbar-cable and busbar joints with Z931 Strippex?
A) Best-in-World Technology: Air-dry rubberised coating seals, insulates and locks joints to 2 kV (11 kV bulk) against vibration — and colour-codes them.
SHP edge — repels dust & water: Repels the moisture and dust that corrode and loosen joints — corrosion is the root cause.
B) Unique Customer Gain: Joints stay tight — no arcing, sparking, overheating, current loss or fire.
Water beading off a coated circuit board.
Water beading off a coated circuit board.
17. #6004 Kleer Kote SHP — PCB Protection
Why protect PCBs and electronics with #6004 Kleer Kote coating?
A) Best-in-World Technology: The world’s only SHP PCB coating — transparent, solder-through; will not crack, peel or discolour.
SHP edge — repels dust & water: Repels the moisture and dust that cause leakage and corrosion between tracks — boards stay reliable far longer.
B) Unique Customer Gain: Costly PCBs protected from moisture, dust and fumes — fewer failures, longer electronic life.
Battery terminals sealed against acid and corrosion.
Battery terminals sealed against acid and corrosion.
18. #6006 Battery Terminal Coating (Waxy Film)
Why coat battery terminals with the #6006 waxy protective film?
A) Best-in-World Technology: Airtight, waterproof, acid-resistant waxy film stops sulfation and corrosion — no dismantling needed.
B) Unique Customer Gain: A full year of terminal protection — reliable starting, longer battery life, less maintenance.
Corrosion neutralised on battery terminals.
Corrosion neutralised on battery terminals.
19. #Z911 Corroclean (SP) — Battery Terminal Cleaner
Why clean and neutralise battery terminals with Z911 Corroclean foam?
A) Best-in-World Technology: Thick foam neutralises acid, with a built-in indicator dye — safe cleaning with terminals in place.
B) Unique Customer Gain: Fast, safe in-place cleaning — better connections, longer battery life.
Wall gaps foam-sealed against pests, dust and damp.
Wall gaps foam-sealed against pests, dust and damp.
20. #Z201 Pufseal (1K-S) — Gap-Sealing PU Foam
Why seal cable penetrations and gaps with Z201 Pufseal foam?
A) Best-in-World Technology: Self-expanding PU foam blocks gaps; an EC 43 overcoat adds fire and rat resistance.
B) Unique Customer Gain: Seals out dust, moisture, rats and insects — protects equipment, prevents costly damage.
A leaking transformer sealed without shutdown.
A leaking transformer sealed without shutdown.
21. #Z982 Transformer Oil Leakage Repair Kit
Why keep the Z982 transformer oil leakage repair kit ready?
A) Best-in-World Technology: The world’s best kit — plugs and re-strengthens transformer oil leaks instantly: clean, plug, overlay.
B) Unique Customer Gain: Stops oil leaks on the spot, without shutdown — prevents transformer damage and oil loss.
Copper and aluminium bus bars safely cleaned.
Copper and aluminium bus bars safely cleaned.
22. #Z112 Acidifoam — Cu/Al Bus-Bar Cleaning
Why clean copper and aluminium bus bars with Z112 Acidifoam?
A) Best-in-World Technology: Safe, high-foam, phosphate-free cleaner for copper, aluminium and steel — no risk to user or equipment.
B) Unique Customer Gain: Clean bus bars safely — better conductivity, no damage, safer for operators.
Hard scale stripped before anti-track coating.
Hard scale stripped before anti-track coating.
23. #Z118 EQC-10 — Insulator Scale Remover
Why use Z118 EQC-10 before applying anti-track coatings on insulators?
A) Best-in-World Technology: Fast liquid acid remover strips hard, cement-like deposits before anti-track coating.
B) Unique Customer Gain: A clean, scale-free surface — anti-track coatings bond better and last far longer.
Steel structures cold-galvanised against rust.
Steel structures cold-galvanised against rust.
24. #7007 Cold Galvanizing Compound SHP
Why use #7007 cold galvanizing for field touch-up on steel structures?
A) Best-in-World Technology: The world’s only SHP zinc coating — 93% zinc gives true cathodic protection.
SHP edge — repels dust & water: Repels the rain and dust that cause corrosion — so zinc protection lasts far longer outdoors.
B) Unique Customer Gain: Towers, pylons and poles stay rust-free for years — fewer repairs, longer life.
A busbar isolator jaw kept cool and tight.
A busbar isolator jaw kept cool and tight.
25. #8078 (DGCS) Dry Graphite Conductive Sealant
Why apply #8078 dry graphite sealant on high-voltage joints and bus-bars?
A) Best-in-World Technology: 100% dry graphite prevents bi-metallic corrosion, arcing and overheating — non-flammable, non-flaking.
B) Unique Customer Gain: Cooler, tighter HV joints — no overheating, jamming, loosening or costly unplanned outages.
Pinpointing a leak on a pressurised line.
Pinpointing a leak on a pressurised line.
26. #Super 230 — Gas Leak Detection Spray
Why use Super 230 spray for detecting gas and air leaks?
A) Best-in-World Technology: Fast, reliable, non-flammable spray pinpoints leaks in pressurised pipes, SF6 breakers and gas lines.
B) Unique Customer Gain: Find leaks instantly and safely — prevents gas loss, downtime and hazards.
Current-carrying contacts greased against heat.
Current-carrying contacts greased against heat.
27. SL-ECG #2 Electrotherm — Contact Grease
Why apply Electrotherm contact grease on current-carrying connections and contacts?
A) Best-in-World Technology: Synthetic grease prevents overheating and corrosion — and uniquely improves current flow through quantum tunnelling.
B) Unique Customer Gain: Cooler, longer-lasting contacts — better conductivity, fewer failures, less maintenance.
HT motor bearings greased; friction and leakage cut.
HT motor bearings greased; friction and leakage cut.
28. Superquiet 100 — HT Motor Grease
Why lubricate HT electric-motor bearings with Superquiet 100 synthetic grease?
A) Best-in-World Technology: The world’s best synthetic grease — never leaks into windings; PTFE cuts friction and extends bearing life.
B) Unique Customer Gain: Protects HT motors from grease-caused failure — longer bearing life, fewer breakdowns.
A seized, rusted bolt freed fast.
A seized, rusted bolt freed fast.
29. #6030 Pen Oil — Heavy-Duty Penetrant
Why keep #6030 Pen Oil for severely seized, rusted assemblies?
A) Best-in-World Technology: Heavy-duty penetrant loosens rust where nothing else can — if it can’t, nothing can.
B) Unique Customer Gain: Frees seized parts fast — saves time, labour and the cost of replacing jammed assemblies.
DIELECTRIC FLOOR COATING
A certified dielectric floor in a panel room.
A certified dielectric floor in a panel room.
30. 1311 Stangard Insulkote (Class A, B & C) — Dielectric Flooring
Why install 1311 Insulkote dielectric flooring instead of rubber mats?
A) Best-in-World Technology: India’s only “legal” flooring — passes all six IS 15652:2006 tests. Nano-ceramic fillers give best-in-class scratch resistance; the moisture-tolerant primer will not peel; proven 10-year life.
B) Unique Customer Gain: Certified shock protection for operators, plus legal compliance — clean, dust-free panel rooms for years.
TRANSFORMER & HIGH-VOLTAGE INSULATION & PROTECTION
HV lines insulated against flashover.
HV lines insulated against flashover.
31. HVI 33 KV — High-Voltage Insulation
Why coat HV lines and bus bars with HVI 33 KV insulation?
A) Best-in-World Technology: The world’s best insulation — prevents flashovers from fog, pollution, animals and kite thread on 11–66 kV systems.
B) Unique Customer Gain: Reliable high-voltage supply — fewer outages, less equipment damage, lower downtime costs.
Self-fusing tape weatherproofing an HV joint.
Self-fusing tape weatherproofing an HV joint.
32. #Z955 Strippex (SL) — Self-Fusing High-Temp Tape
Why insulate heavily-loaded HV connections with Z955 self-fusing silicone tape?
A) Best-in-World Technology: Self-fusing silicone tape permanently weatherproofs 600 V–35 kV joints up to +300 °C — and never loosens.
B) Unique Customer Gain: Permanent, secure HV insulation — no loosening, fewer faults, safer connections.
DIELECTRIC ANTI-CORROSION
A high-value transformer protected from corrosion.
A high-value transformer protected from corrosion.
33. 1040 TST + 727 SHP — Anti-Corrosion System
Why protect transformers with the 1040 TST + 727 SHP system?
A) Best-in-World Technology: The world’s best surface-tolerant epoxy-PU — bonds to oily, rusty metal; fast anti-corrosion with minimum shutdown.
SHP edge — repels dust & water: The 727 top coat repels dust and moisture — the cause of corrosion — and stays weather-resistant, durable and easy to clean.
B) Unique Customer Gain: Prevents corrosion-driven oil leaks — the cause of costly transformer damage and major fires — and protects a high-value asset.
A distribution pole coated and shock-safe to 11 kV.
A distribution pole coated and shock-safe to 11 kV.
34. #2080 Electrohyb SHP — Hybrid Polymer Insulation
Why use #2080 Electrohyb for dielectric anti-corrosion and leakage protection?
A) Best-in-World Technology: The world’s first SHP dielectric coating — 26.5 kV/mm strength, shock-safe to 11 kV, self-extinguishing in fire.
SHP edge — repels dust & water: Repels the dust and moisture that cause corrosion, leakage and arcing on poles, panels and bus bars.
B) Unique Customer Gain: Shock-safe to 11 kV — prevents accidental electrocution of people and animals, plus long-lasting anti-corrosion.
Legal stakes: an electrocution death is a personal criminal offence for the owner, director and manager — and uninsurable.
www.stanvac.com  |  +91-8527-1998-11  |  digitalmktg@stanvac.com
Home Download PDF