RRI / Control Room with Firefighting Provision  |  January 2019

Government guideline for railway relay-interlocking and control-room buildings

Railway relay-interlocking control-room building beside electrified tracks and a signal

RAILWAY
CONTROL ROOMS.

FIRE SAFETY.
SIGNALLING PROTECTED.

Government guidance.
Stanvac technology. Your gain.

6 APPLICATIONS  /  RELAY ROOMS · CABLES · OPENINGS · ALARM CIRCUITS

01

RELAY-ROOM WALL OPENINGS

Unsealed cable entry through a relay-room wall; inset: AFTER, the opening sealed around the cables

An unsealed entry lets fire and smoke reach the relay
room.

RDSO/WKS/2018/2 · 3.10(c)

Seal service penetrations through walls and floors of
gas-protected enclosures.

STANVAC SOLUTION

FM 71 + FB250 HYBRID COMBO

Mortar strength + mineral-wool boards: load-bearing safety
+ easier cable retrofitting, with the specified supports and
tested assembly.

YOUR GAIN

Protect room boundaries. Keep cable changes
manageable.

Match the tested opening and required fire rating. Gas-suppression enclosure
integrity must be verified separately.

02

FLOOR + CABLE-VOID PENETRATIONS

Open floor penetration with cables dropping into a cable void; inset: AFTER, the opening sealed with a firestop board

An open floor penetration links separate fire areas.

RDSO/WKS/2018/2 · 3.10(c)

The enclosure-sealing guidance also covers cable, duct and
pipe openings through floors.

STANVAC SOLUTION

FM 71 + FB250 HYBRID COMBO

Use the matching 2-hour tested hybrid where suitable:
mortar strength and mineral-wool boards with provision for
cable re-entry.

YOUR GAIN

Limit fire spread through floor openings. Simplify
retrofits.

Match orientation, services, seal depth and support detail. Reinstate the barrier
after every cable change.

03

FIRE SPREAD ALONG ROOM CABLES

Fire and smoke spreading along cable trays in an equipment room; inset: AFTER, the coated cable trays

A small cable fire can disable an entire signalling
room.

RDSO/WKS/2018/2 · SECTION 6

Discusses intumescent coatings as a means of delaying fire
spread and heat reaching suitable substrates.

STANVAC SOLUTION

EC 43 GENERAL

Stanvac’s cable-specific proposal: protect sound sheaths with
a system reporting 240-minute IEC 60332-3 flame-spread
performance at 1.6 mm.

YOUR GAIN

Limit flame travel through dense cable routes.

This is an application proposal, not an RDSO-approved product claim. Obtain
project acceptance for cable type, loading and installation.

04

POWER-ROOM JOINTS + TERMINATIONS

Cracked, burnt cable joint at a power-room termination; inset: AFTER, the joint protected with a flexible coating

Damaged joint protection can become a fire starting
point.

RDSO/WKS/2018/2 · SECTION 6.2

Addresses electrical-fire causes and prevention, including
overheating and unsafe temporary connections.

STANVAC SOLUTION

931B STRIPPEX INTUMESCENT

Protect suitable repaired joint exteriors with flexible
insulation + dust and water repellency. Reported
120-minute IEC 60332 test.

YOUR GAIN

Reduce contamination at repaired joints. Add
flame-spread resistance.

First correct overheating, loose connections and damaged insulation. Do not coat
contacts, relay mechanisms or ventilation paths.

05

RODENT EXPOSURE AT CABLE ENTRIES

Rodent at a cable entry with bitten wires; inset: AFTER, the cables coated with translucent anti-rodent coating

One bitten wire can interrupt signalling.

RDSO/WKS/2018/2 · SECTION 6

Calls for cable entrances to equipment housings to exclude
moisture, rodents, termites and insects, with removable seals.

STANVAC SOLUTION

EC 7034 · ADDED CABLE PROTECTION

Flexible, translucent anti-rodent coating on sound cable
sheaths. Reported 0 bites in a 30-day test; wire colours
remain visible.

YOUR GAIN

Reduce bite-related faults in vulnerable wiring.

Cable coating supplements the required entrance seal. Use FM 71 + FB250 at
fire-rated building penetrations; confirm re-entry and rating details.

06

FIRE-DETECTION + RESPONSE FEEDS

Alarm sounder and detector cables on a cable tray near a fire; inset: AFTER, the response-circuit cables coated

A detector is useful only if its signal reaches the
system.

RDSO/WKS/2018/2 · SECTION 8

Provides guidance for automatic fire detection and alarm
systems in these installations.

STANVAC SOLUTION

EC 43 SURVIVAL

Additional protection for selected, compatible response-circuit
cables. Reported 240 min at 750°C, IEC 60331-21, on the
tested system.

YOUR GAIN

Support alarm continuity and timely response.

Retain approved detection, suppression and backup power. Do not coat
detectors, sensing cables or sampling holes. Obtain railway acceptance.

THE TEST MUST MATCH THE PROTECTION YOU NEED.

0 BITES

EC 7034

30-day rodent test
RDSO/SPN/204
Sound cable sheaths only

240 MIN

EC 43 GENERAL

Flame-spread test
IEC 60332-3
1.6 mm test build

240 MIN

EC 43 SURVIVAL

Circuit survival at 750°C
IEC 60331-21
4-core × 70 mm² XLPE / 1.6 mm

2 HOURS

FM 71 + FB250
HYBRID COMBO

Penetration firestop
IS 12458
Match the tested assembly

Performance figures are reported by Stanvac for specific tested systems. Obtain the matching test report and installation detail. Flame-spread resistance,
circuit survival and penetration fire resistance are different performances.

START WITH YOUR MOST VULNERABLE AREA.

Send cable-route, panel and opening photos.

Ask Stanvac for a site survey, system specification and offer.

GOVERNMENT SOURCE RDSO/WKS/2018/2, January 2019: Guideline on Construction of RRI Room / Control Room with Firefighting Provision; §§3.10, 6 and 8. Clause
summaries are paraphrased.

PRODUCT DETAILS EC 43 / EC 7034 · FM 71 + FB250 HYBRID COMBO · 931B STRIPPEX

Building applications for RRI / control rooms. Confirm current Railway Board, zonal and tender requirements. Product proposals require railway acceptance; they are not
RDSO product approvals or rolling-stock specifications.

Selected sales applications, not a complete fire-safety checklist. Stanvac proposals do not imply government endorsement or whole-facility compliance. AI sector and
application illustrations; “after” shows treatment, not a verified installation or fire-test result. Repair or replace defective cables before coating.