FIREX EC 7034
ANTI-RODENT CABLE COATING · CABLE FIRE PROTECTION
PROTECT THE CABLE. PROTECT THE PLANT.
RATS BITE CABLES
One bite can cause fire or stop production.

Bitten insulation. Exposed copper.
The risk remains.
30-DAY RODENT TEST
19
BITE MARKS
Uncoated cable
0
BITE MARKS
7034-coated
cable
Same cages. Same 30 days.
Food freely available.
RDSO/SPN/204 Annexure G — NABL lab
Rodent classification: SAFE
ONE COATING. TWO PROTECTIONS.
120 min
FLAME-SPREAD TEST
CBRI — IEC 60332-3-22, Category A
Helps limit flame spread along coated cables.
Tested build: 1.5 mm, directly on the cable.
WORLD FIRST
Intumescent cable coating:
translucent, flexible and anti-rodent.
THE LOSS GOES BEYOND THE CABLE.
Rat bite
Exposed conductor
Electrical fault
Fire / shutdown

Cable fire.
Production at risk.
A cable fault can mean
Fault-finding
Cable replacement
Production loss
Restart delays
ALREADY PAYING FOR PEST CONTROL?
Protect the cable too.
Pest control reduces rodent activity. 7034 protects the cable. Use both.
PROTECT THE WIRING INSIDE PANELS

Thin-diameter panel wiring.
One bitten wire can stop a machine.
Thin wires. Easy targets for rats.
7034: Translucent. Flexible.
Rat-bite + flame-spread protection.
Keep wire identification visible.
Hard, opaque coats hide wire ID
and can complicate replacement.
Panels · DBs · Junction boxes.
Coat sound insulated wiring. Isolate first; keep contacts, terminals and moving parts clear.
FIRE-COATED. RODENT-PROTECTED?
Keep the fire coat. Add 7034.

Large-diameter cable routes.
Protect coated and uncoated cables.
Fire coatings may lack rodent protection.
Add 7034 over compatible, firmly adhered
coatings on indoor fixed cables.
Uncoated cables?
Apply 7034 to sound cable sheaths.
Check adhesion and compatibility.
Use the Stanvac-approved system.
Over existing fire coats: 0.5 mm.
The tested 1.5 mm direct-to-cable ratings do not automatically apply to combined systems.
Start with one critical panel or cable route.
Get the coating specification, test reports and price.
WHERE CABLE PROTECTION MATTERS
Protect production, essential services and people.
FOOD, PHARMA & STORAGE
Food, dairy & beverage
Grain, sugar, rice & feed mills
Cold storage & warehouses
Pharma & FMCG
BUILDINGS & TRANSPORT
Hospitals · Hotels · Malls
Cinemas · High-rise buildings
Railways · Metro · Airports
POWER, DATA & INDUSTRY
Data centres & telecom
Substations · Solar & batteries
Refineries & petrochemicals
Fertiliser · Steel · Cement · Mines
Panels · Cable trays · Trenches · Risers · Service shafts
GAPS LET RATS IN
Seal the entry. Protect more than cables.
AC insulation · Foams · Plastic ducting

Close large wall & floor openings.
LARGE OPENINGS
FM 71
Firestop mortar.
Seal around cables
and pipes.

Narrow, congested cavities.
Application illustration
DIFFICULT ACCESS
PUFSEAL
+ 7034 TOPCOAT
Fill the cavity.
7034 protects the foam
from rat bites.
For non-rated gaps & cavities.

Close gaps around individual entries.
SMALL GAPS
FBS 73
Flexible firestop putty.
Mould around cable
and pipe entries.
COAT THIN & LARGE CABLES.
SEAL EVERY OPENING.
Send cable and opening photos.
Get the recommended system and quotation.
+91 85271 99811
digitalmktg@stanvac.com
Keeping People Safe. Keeping Plants Running.