RDSO/SPN/204 Annexure G · NABL
IEC 60332-3-22 · Category A · CBRI
| Industry | Why the rodents are there | Where to coat | |
|---|---|---|---|
| 01 | Food processing, dairy & beverage | The product is food. Spillage, wash-down warmth and motor rooms run around the clock. | Trays over production and packing lines · MCC and panel room interiors · utility and chiller corridors |
| 02 | Grain, sugar, rice & feed mills | Stored grain is the densest rodent habitat in Indian industry. | Conveyor gallery runs · silo and elevator wiring · mill floor panels and DBs |
| 03 | Cold storage & warehousing | Warm plant rooms sit beside chilled halls. Almost nobody is there at night. | Compressor and plant room runs · racking-level conduit · dock and dispatch panels |
| 04 | Pharmaceutical & FMCG | Service voids, false ceilings and shafts run above clean rooms. | Shaft runs above clean areas · service void cabling · AHU and utility panel interiors |
| Industry | Why the rodents are there | Where to coat | |
|---|---|---|---|
| 05 | Hospitals & healthcare | Kitchens, waste rooms, laundry and round-the-clock warmth. Rodents travel the same shafts and false ceilings as the cabling. | Riser shafts · false-ceiling runs over wards and corridors · ward, OT and diagnostic DBs |
| 06 | Hotels, malls & cinemas | Kitchens and garbage rooms feed the whole building. Rodents then take the service shafts. | Kitchen and back-of-house runs · vertical service shafts · basement car-park trays |
| 07 | High-rise commercial | Basements, refuge floors and riser shafts run the height of the building. | Riser shafts · basement cable trays · floor DB and meter-room interiors |
| 08 | Railways, metro & airports | Signalling troughs, tunnels, station voids, platform catering and cargo sheds. | Signalling and telecom trough runs · tunnel and station-void cabling · cargo-shed trays |
| Industry | Why the rodents are there | Where to coat | |
|---|---|---|---|
| 09 | Data centres & telecom exchanges | Under-floor voids and ceiling plenums are sheltered, undisturbed routes. | Under-floor and plenum runs · tray routes feeding racks · MDB and UPS-room cabling |
| 10 | Substations & cable basements | Trenches, ducts and burrows run under the switchyard. Basements are dark, warm and rarely entered. | Basement and trench runs · duct and gland entries · control and relay-panel interiors |
| 11 | Solar plants & battery storage | Rural sites. Burrows under module rows; string and DC cable at grade. | String and DC cable at grade · combiner-box interiors · inverter and battery-room runs |
| 12 | Refineries, petrochemical & fertiliser | Mains are armoured. Control and instrumentation cable, panel interiors and tray runs are not. | Control and instrumentation trays · panel and junction-box interiors · sleeper crossings |
| 13 | Steel, cement, mines & heavy industry | Canteens, stores and substation rooms carry the rodent load into the plant. Pit-head and workshop equipment is cabled throughout. | MCC and substation-room runs · exposed control cabling · DB, starter and machine-panel interiors |
Every plant on this list already pays a pest-control contractor. He baits, traps and seals the room — and has never touched the one surface that actually starts the fire. FIREX EC 7034 protects at the cable itself — and the same coating denies the cable sheathing as fuel if a fault still starts.
The exposed conductor can arc against nearby components and start a fire inside the box.
Panels, junction boxes, distribution boards, control cabinets, machinery and mining-equipment enclosures. The rodent gets in by the same route the cable does — the gland, the knockout or the cutout at the base.
Coat the wiring and exposed surfaces inside. The rodent is turned away at the film; if a fault still starts — from a rat or a loose termination — the coating denies the wiring as fuel, so flame does not travel out of the box along the cable and down the tray.
Many plants that protected cable runs against fire years ago already carry a water-based intumescent coating. That coating may carry no anti-rodent protection, no RDSO/SPN/204 Annexure G test and no rodent rating. A run can be fire-protected and rodent-unprotected.
On a sound, adhered and compatible existing coat, 7034 can be applied as the anti-rodent overcoat on indoor cable trays, cellars, basements, riser shafts, galleries and plant rooms. Nothing is stripped, re-pulled or taken out of service. The plant keeps the fire coat already paid for and gains the defence it never had.