FIVE CRITICAL AREAS.
ONE STANVAC SOLUTION SET.
Priority protection for critical drives.
HT motors. No standby. Repeated failures.
Moisture, oil and dust can lower insulation resistance (IR).
#8060 SAFETY SOLVENT
Non-flammable, residue-free dielectric cleaner
Removes oil and grease from winding surfaces.
#8070 ELECTRICAL 88 SHP
Heavier-than-water moisture displacer
Helps recover IR lost to surface moisture.
#6084 RED VARNISH SHP
Fast-drying Class F insulating varnish
Repels water and dust; shields windings from fumes.
Varnish needs an approved clean, dry surface preparation sequence. Verify IR before restart.
Protect the bearing and nearby windings.
SUPERQUIET 100
100% synthetic. PTFE-fortified motor grease.
Grease-lubricated bearings only. Confirm motor-OEM speed, temperature, quantity and grease compatibility.
#415 OFF-LINE CONTACT CLEANER
Plastic-safe, residue-free cleaner
Removes contact contamination for reliable connections.
Z931(A) STRIPPEX SHP
Rubberised external insulation
Seals assembled joint exteriors against moisture and dust.
#1465(A) FLEXIGUARD SHP
Flexible, fire-retardant joint sealer
Seals tape overlaps and aged sheathing against moisture and dust.
Apply external insulation after assembly and torque checks. Keep contact faces uncoated; confirm voltage suitability.
1465: over sound, correctly insulated taped joints. Confirm compatibility with the tape and cable sheath.
Cable damage can stop a healthy motor.
FIREX EC 43 GENERAL
Suppress flame spread on the motor supply cable.
Published 240-minute flame-propagation test
IEC 60332-3 · 1.6 mm dry film
FIREX EC 43 / SURVIVAL
Help preserve the motor’s cable circuit during fire.
950°C / 180 minutes · IS 17505-1
750°C / 240 minutes + 15 minutes cooling
IEC 60331-21
Published survival tests: low-voltage, 4-core 70 mm² XLPE cable at 1.6 mm dry film. Circuit-survival ratings must match operating voltage and cable construction.
ADD RODENT PROTECTION
FIREX 7034
Protect the motor’s supply cable from rodent damage.
Add a 0.5 mm topcoat over EC 43 where specified.
View published cable performance
Z704 RUSTEX-NMB
Rust-converting primer
Treats residual rust on ferrous casings and bases.
2050 POLYHYB SHP
Protective outer finish
Repels water and dust; reduces repeat repainting.
Z730 STEELWELD
Machinable metal-repair putty
Rebuilds approved worn housings, keyways and shaft seats.
Z704: ferrous surfaces, 1-70°C. 2050: C1-C3 exterior exposure. Hot, wet, coastal or chemical duty needs a specific coating system.
Use Z730 where wear requires repair. Assess the component and machine to approved final tolerances.
A UNIQUE COMBINATION
FOR MOTOR FAILURE PREVENTION.
Windings. Bearings. Joints. Motor cable. Casing.