Stanvac

ELECTRICAL WHY BUY / 2026

THE STANVAC
ELECTRICAL ADVANTAGE

34

MAINTENANCE PROBLEMS

WITH INDIA’S BEST SOLUTIONS

WHY BUY?

THE TECHNOLOGY
DIFFERENCE.

YOUR UNIQUE GAIN.

A small panel fire can spread along cables, cutting power and stopping production across the plant.

A small panel fire can spread along cables,
cutting power and stopping production across
the plant.

SHP = built-in dust & water repellency. Helps reduce the contamination that contributes to leakage,
tracking, arcing and corrosion.

ALSO DELIVERED TURNKEY

ONE VENDOR. ONE WARRANTY. TESTED OUTCOMES.

01

PASSIVE FIRE PROTECTION

Protect panels, cables and openings against the spread of fire.

STANVAC PCO - PANELS. CABLES. OPENINGS.

Defend each link: panel spark → small wire → cable highway → openings.

01

FIREX FBS 73 - Fire Sealant

Open panel gaps let in dust, moisture and pests, while incoming air supplies oxygen that can feed a fire.

Open panel gaps let in dust,
moisture and pests, while incoming
air supplies oxygen that can feed a
fire.

Applications. Electrical-panel gaps and cable
entries.

Technology. India's first oxygen-limiting panel
sealant. Flexible and re-enterable; tested up to 2
hours to IS 12458 in the specified arrangement.

Customer gain. Seal out dust, moisture and
pests. Help stop small faults becoming larger
panel fires.

02

FIREX DC 52 - Fire-Suppression Paint

Combustible panel paint can feed a small electrical fire, increasing damage inside the panel.

Combustible panel paint can feed a
small electrical fire, increasing
damage inside the panel.

Applications. Internal painted surfaces of
electrical panels and cabinets.

Technology. India's first intumescent fire-barrier
panel coating. Limits panel paint feeding a fire and
provides a thermal shield.

Customer gain. Help contain fire at source.
Reduce equipment damage and production
downtime.

3A

FIREX EC 43 - Circuit Survival

Even brief fire exposure can damage cables and force replacement, causing major disruption. Pumps, ventilation and emergency lighting can fail when needed most.

Even brief fire exposure can damage
cables and force replacement,
causing major disruption. Pumps,
ventilation and emergency lighting
can fail when needed most.

Applications. Critical-circuit cables that must
operate during a fire.

Technology. World-first fire-survival cable
coating. At 1.6 mm on XLPE 4-core 70 mm²: 180
minutes at 950°C (IS 17505-1); 240 minutes plus
15 minutes cooling at 750°C (IEC 60331-21).

Customer gain. Keep tested circuits working
for the certified duration. Add the specified 0.5
mm 7034 topcoat for anti-rodent protection.

3B

FIREX EC 43 - Flame-Propagation Protection

Cable fires can spread along trays through the plant, and toxic smoke can kill. Limiting flame spread helps buy time to identify and control the fire and evacuate personnel.

Cable fires can spread along trays
through the plant, and toxic smoke
can kill. Limiting flame spread helps
buy time to identify and control the
fire and evacuate personnel.

Applications. Cable trays and cable highways.

Technology. CBRI-certified, low-smoke coating:
240-minute flame-propagation performance at 1.6
mm to IEC 60332-3. Circuit survival is covered in
3A.

Customer gain. Limit a local cable fire
spreading through the plant. Add the specified
0.5 mm 7034 topcoat on rodent-prone routes.

3C

931B STRIPPEX - INTUMESCENT

Cracked cable sheathing increases breakdown risk; combustible tape at cable and busbar joints can feed a fire.

Cracked cable sheathing increases
breakdown risk; combustible tape at
cable and busbar joints can feed a
fire.

Applications. Taped connections, cable joints,
busbar and lug joints.

Technology. Rubberised SHP base + top coat. Up
to 11 kV insulation test before fire; 120-min IEC
60332 flame-spread test (CSIR-CBRI). HT: use with
955 SL tape.

Customer gain. Taped joints and cracked cable
joints can cause breakdowns and fires. 931B
protects repaired joints and limits flame spread.

04

FIREX 7034 - Anti-Rodent Cable Coating

Rat bites, especially on small-diameter panel cables, can cause short circuits, fire and shutdowns. Protection must stay flexible and translucent, keeping wire colours visible.

Rat bites, especially on small-
diameter panel cables, can cause
short circuits, fire and shutdowns.
Protection must stay flexible and
translucent, keeping wire colours
visible.

Applications. Small-diameter power, data and
instrumentation cables, including panel wiring.

Technology. World's first translucent, flexible
anti-rodent intumescent coating. 30-day test: 0
bites coated vs 19 uncoated; SAFE, RDSO/SPN/204
Annex. G. CBRI: 120 min, IEC 60332-3-22 Cat. A at
1.5 mm on cable.

Customer gain. Resist rodent bites and fire
spread. Keep cable colours visible and wiring
flexible.

05

FIREX FM 71 - Fire-Stop Mortar

Unsealed wall and floor openings let fire and smoke spread. Use load-bearing firestop sealing where load support is needed.

Unsealed wall and floor openings let
fire and smoke spread. Use load-
bearing firestop sealing where load
support is needed.

Applications. Cable openings in walls and floors.

Technology. CSIR-CBRI tested: 2 hours at 75 mm
to IS 12458; published 20-year life. Options: 75
mm FM 71 or a specified 50 mm FM 71 + 50 mm
FB 250 hybrid.

Customer gain. Limit fire and smoke spread
between rooms and floors. A one-foot EC 43
cable coat addresses the fire path along cables.

06

FIREX FB 250 - Mineral-Wool Fire Barrier

Unsealed wall openings let fire and smoke spread. Easy retrofit sealing closes gaps around existing cables and allows future cable changes.

Unsealed wall openings let fire and
smoke spread. Easy retrofit sealing
closes gaps around existing cables
and allows future cable changes.

Applications. Cable penetrations needing future
cable changes.

Technology. Re-enterable mineral-wool barrier:
100 mm / 2 hours to IS 12458 (CSIR-CBRI).
Specified FM 71 + FB 250 + EC 43 hybrids can
extend protection to 4 hours.

Customer gain. Add or change cables and
reinstate the seal. Combine with FM 71 for
load-bearing capability.

02

CLEANING, INSULATION & PROTECTION

Clean, insulate and protect electrical assets for more reliable service.

07

#901 Easy Clean CO₂ 360 SHP NF

Dusty panels can cause faults; shutting down for cleaning costs production. On-line cleaning must be plastic-safe.

Dusty panels can cause faults;
shutting down for cleaning costs
production. On-line cleaning must
be plastic-safe.

Applications. On-line panel relays, contactors
and plastic-sensitive surfaces.

Technology. Non-flammable, plastic-compatible
cleaner with CO₂ 360° spray. SHP repels dust and
moisture.

Customer gain. Clean suitable equipment
without a shutdown. Reduce production loss and
contamination-related faults.

08

#415 Off-Line Contact Cleaner CO₂ 360 SHP

Dirty switch and relay contacts can cause intermittent faults and unreliable switching.

Dirty switch and relay contacts can
cause intermittent faults and
unreliable switching.

Applications. Isolated switches, relays and
contactors.

Technology. Plastic-compatible, CFC-free
cleaner. Fast drying; no residue. SHP repels dust
and moisture.

Customer gain. Reduce switching faults and
extend the interval between cleanings.

09

#8376 Electronic Component Cleaner

Dirty PCBs can disrupt controls, but strong-smelling cleaners are difficult to use in air-conditioned control rooms.

Dirty PCBs can disrupt controls, but
strong-smelling cleaners are difficult
to use in air-conditioned control
rooms.

Applications. Sensitive PCBs and electronics in
AC control rooms.

Technology. Low-odour, plastic-compatible,
residue-free cleaner. CO₂ 360° spray; SHP dust
and moisture repellency.

Customer gain. Clean electronics with minimal
odour and no residue. Help prevent
moisture-related tracking and leakage.

10

#8060 Safety Solvent CO₂ 360 NF

Heavy oil and grease trap dirt on electrical equipment; removing them can mean lengthy cleaning and shutdowns.

Heavy oil and grease trap dirt on
electrical equipment; removing them
can mean lengthy cleaning and
shutdowns.

Applications. Heavy oil and grease on electrical
equipment.

Technology. Non-flammable, dielectric cleaner
with CO₂ 360° spray. Removes oil and grease
without residue.

Customer gain. Deep-clean suitable equipment
in place. Reduce dismantling and cleaning
downtime.

11

#8070 Electrical 88 CO₂ SHP

In damp areas, near cooling towers and at coastal plants, moisture on motors, switches, contactors and busbars can cause trips and flashovers.

In damp areas, near cooling towers
and at coastal plants, moisture on
motors, switches, contactors and
busbars can cause trips and
flashovers.

Applications. Damp motor windings and bus bars
in humid, coastal and monsoon conditions.

Technology. Heavier-than-water formula
displaces moisture and helps restore insulation
resistance. SHP repels dust and water.

Customer gain. Reduce moisture-related
flashovers. Published protection: up to six
months under specified conditions.

12

#8480 Carbon Cleaner

Scraping burnt-on carbon or rubbing contacts with emery paper can scratch costly contact surfaces.

Scraping burnt-on carbon or rubbing
contacts with emery paper can
scratch costly contact surfaces.

Applications. Flashover carbon on contacts,
commutators and contactors.

Technology. Thick-film foam gel lifts heavy
carbon without abrasives; compatible with
specified silver and copper surfaces.

Customer gain. Clean without scratching.
Extend contact life and reduce replacement.

13

#6084 Red Insulating Varnish SHP - Class F

Dust, moisture and chemical fumes can damage motor-winding insulation, leading to costly rewinds.

Dust, moisture and chemical fumes
can damage motor-winding
insulation, leading to costly rewinds.

Applications. Motor winding end-turns,
accessible through opened end covers.

Technology. Fast-drying SHP varnish coats
windings in place. Resists arcing and tracking;
repels dust and moisture.

Customer gain. Preserve insulation resistance.
Extend motor life and reduce costly rewinds.

14

#Z906 Provar Anti-Track SHP - Class H

Dust and moisture on panel and switchyard insulators can create leakage paths, causing tracking, flashovers and power interruptions.

Dust and moisture on panel and
switchyard insulators can create
leakage paths, causing tracking,
flashovers and power interruptions.

Applications. Panel insulators, current
transformers and potential transformers.

Technology. High-dielectric-strength SHP coating
helps restore insulation resistance. Repels dust
and moisture that cause surface tracking.

Customer gain. Reduce flashovers and panel
breakdowns. Keep metering reliable for longer.

15

#1465(A) Flexiguard SHP

Cracked cable sheaths and ageing joints let moisture in, increasing breakdown risk.

Cracked cable sheaths and ageing
joints let moisture in, increasing
breakdown risk.

Applications. Cable joints and cracked or aged
cable sheathing.

Technology. Flexible, fire-retardant SHP coating
bonds to specified PVC, rubber and metal. Repels
dust and moisture.

Customer gain. Keep moisture out of damaged
sheathing and joints. Extend cable service life.

16

#Z931(A) Strippex SHP

Poorly sealed cable and busbar joints let moisture in, increasing corrosion, arcing and breakdown risk.

Poorly sealed cable and busbar
joints let moisture in, increasing
corrosion, arcing and breakdown
risk.

Applications. Motor-cable, busbar-cable and
assembled bus-bar joints.

Technology. Air-drying rubberised coating seals,
insulates and colour-codes joints. Ratings: 2 kV
aerosol / 11 kV bulk, as specified. SHP repels dust
and water.

Customer gain. Protect connections from
moisture and corrosion. Reduce arcing,
overheating and connection failures.

17

#6004 Kleer Kote SHP

Dust, moisture and fumes on PCBs can cause corrosion and repeated electronic failures.

Dust, moisture and fumes on PCBs
can cause corrosion and repeated
electronic failures.

Applications. PCBs exposed to dust, moisture
and fumes.

Technology. Transparent, solder-through SHP
coating. Repels dust and water; resists cracking,
peeling and discolouration.

Customer gain. Reduce leakage and corrosion
between tracks. Protect costly boards and
extend electronic life.

18

#6006 Battery Terminal Coating

Recurring battery-terminal corrosion can cause low battery output, unreliable connections and repeated cleaning.

Recurring battery-terminal corrosion
can cause low battery output,
unreliable connections and repeated
cleaning.

Applications. Cleaned battery terminals.

Technology. Airtight, waterproof, acid-resistant
waxy film. Protects without dismantling; published
protection of at least 12 months.

Customer gain. Reduce corrosion and
sulphation. Keep connections reliable and cut
terminal maintenance.

19

#Z911 Corroclean (SP)

Corroded battery terminals can prevent reliable power delivery, even from a charged battery.

Corroded battery terminals can
prevent reliable power delivery,
even from a charged battery.

Applications. Acid deposits and corrosion on
battery terminals.

Technology. Thick foam neutralises acid. Built-in
indicator dye; cleans suitable terminals in place.

Customer gain. Restore cleaner connections
quickly. Help improve battery reliability and life.

20

#Z201 Pufseal (1K-S)

Unsealed openings in panels and walls let rats and other pests enter and damage cables. Hard-to-reach gaps make sealing difficult.

Unsealed openings in panels and
walls let rats and other pests enter
and damage cables. Hard-to-reach
gaps make sealing difficult.

Applications. Awkward cable-entry gaps and
voids.

Technology. Expanding PU foam for non-rated
gaps. A 7034 topcoat adds rodent resistance to
cured foam; the combination is not a fire-rated
seal.

Customer gain. Block entry paths for dust,
moisture, insects and rodents. Reduce
equipment contamination.

21

#Z982 Transformer Oil Leakage Repair Kit

Continued transformer oil leakage can impair cooling and insulation, causing overheating, transformer failure and costly plant shutdowns.

Continued transformer oil leakage
can impair cooling and insulation,
causing overheating, transformer
failure and costly plant shutdowns.

Applications. Accessible transformer tank leaks
suitable for external repair.

Technology. Clean, plug and overlay: seal the
leak and reinforce the repair.

Customer gain. Stop oil loss on suitable leaks
without a shutdown. Protect the transformer and
reduce oil wastage.

22

#Z112 Acidifoam

Deposits on copper and aluminium contact surfaces can increase resistance and heating.

Deposits on copper and aluminium
contact surfaces can increase
resistance and heating.

Applications. Copper and aluminium bus bars
and compatible metals, during isolated
maintenance.

Technology. High-foam, phosphate-free cleaner
removes deposits from copper, aluminium and
steel.

Customer gain. Restore clean contact surfaces
without abrasive damage. Support reliable
electrical connections.

23

#Z118 EQC-10

Hard, cement-like deposits on insulators are difficult to remove and can prevent protective coatings from bonding.

Hard, cement-like deposits on
insulators are difficult to remove
and can prevent protective coatings
from bonding.

Applications. Insulators with hard, cement-like
deposits.

Technology. Fast-acting acid scale remover
prepares compatible surfaces for anti-track
coatings.

Customer gain. Improve coating adhesion and
help anti-track protection last longer.

24

#7007 Cold Galvanizing Compound SHP

Damaged galvanising leaves switch yard structures, poles and GI earthing wires and strips exposed to rust, especially at welds and bare spots.

Damaged galvanising leaves switch
yard structures, poles and GI
earthing wires and strips exposed to
rust, especially at welds and bare
spots.

Applications. Steel towers, pylons, poles, welds
and damaged galvanised areas.

Technology. 93% zinc provides cathodic
protection. SHP repels rain and dust.

Customer gain. Restore protection at
vulnerable steel areas. Reduce repeat rust
repairs and extend asset life.

25

#8078 DGCS - Dry Graphite Conductive Sealant

Corroded isolator jaws can jam, arc and overheat, making switching unreliable.

Corroded isolator jaws can jam, arc
and overheat, making switching
unreliable.

Applications. Busbar isolator jaw contacts in
specified HV switchgear.

Technology. Dry graphite conductive film limits
bi-metallic corrosion. Non-flammable and
non-flaking.

Customer gain. Reduce jaw jamming, arcing
and overheating. Resist corrosion and keep
isolator switching reliable.

26

Super 230 - Gas Leak Detection Spray

Tiny, hard-to-find leaks in SF6 circuit breakers and compressed-air lines waste gas and reduce pressure, risking downtime.

Tiny, hard-to-find leaks in SF6 circuit
breakers and compressed-air lines
waste gas and reduce pressure,
risking downtime.

Applications. SF₆ breaker valves and joints, gas
lines and compressed-air systems.

Technology. Non-flammable spray pinpoints
escaping gas at accessible joints and fittings.

Customer gain. Find and repair leaks quickly.
Reduce gas loss, equipment downtime and
operating problems.

27

SL-ECG #2 Electrotherm - Contact Grease

High contact resistance at busbar joints wastes power as heat and can damage the connection.

High contact resistance at busbar
joints wastes power as heat and can
damage the connection.

Applications. Bolted busbar joints and specified
current-carrying contact interfaces.

Technology. Synthetic contact grease protects
against corrosion and supports effective current
transfer.

Customer gain. Help reduce power lost as heat
at bolted busbar joints. Limit overheating and
breakdown risk.

28

Superquiet 100 - HT Motor Grease

Grease melting or being thrown off motor bearings can cause bearing wear, winding contamination and costly rewinds.

Grease melting or being thrown off
motor bearings can cause bearing
wear, winding contamination and
costly rewinds.

Applications. HT motor bearings exposed to heat
and grease migration.

Technology. 100% synthetic, PTFE-fortified
grease resists melting and migration. Published
ratings: 180°C and 3,000 rpm.

Customer gain. Keep grease at the bearing
and out of windings. Extend bearing life and
reduce motor failures.

29

#6030 Pen Oil - Heavy-Duty Penetrant

Heavily rusted nuts and bolts seize, delaying dismantling and extending shutdowns.

Heavily rusted nuts and bolts seize,
delaying dismantling and extending
shutdowns.

Applications. Seized nuts, bolts and rusted
assemblies.

Technology. Heavy-duty penetrant works into
rust-bound interfaces to release stubborn
fasteners.

Customer gain. Free the part with less time
and labour. Reduce damage and replacement
costs.

03

DIELECTRIC FLOOR COATING

Provide specified operator protection with a continuous floor system.

30

1311 Stangard Insulkote - Class A, B & C

An electrical fault can expose panel operators standing on conductive floors to severe electric shock.

An electrical fault can expose panel
operators standing on conductive
floors to severe electric shock.

Applications. Electrical-panel operating floors.

Technology. Tested to all six IS 15652:2006
requirements. Nano-ceramic fillers improve
scratch resistance; moisture-tolerant primer
improves adhesion. Published life: 10 years.

Customer gain. Provide specified operator
shock protection with a continuous, cleanable
floor. Keep panel rooms cleaner and dust-free.

04

TRANSFORMER & HIGH-VOLTAGE INSULATION

Protect high-voltage connections from flashovers and environmental exposure.

31

HVI 33 KV - High-Voltage Insulation

Fog, pollution, animal contact or kite thread can trigger HV flashovers and interrupt the power supply.

Fog, pollution, animal contact or kite
thread can trigger HV flashovers and
interrupt the power supply.

Applications. HV lines and bus bars exposed to
fog, pollution, animals and kite thread.

Technology. Protective insulation coating
reduces flashovers from contamination and
accidental bridging, within specified system
ratings.

Customer gain. Reduce power outages,
equipment damage and downtime.

32

#Z955 Strippex (SL) - Self-Fusing Tape

Loose or damaged tape at HV cable joints lets moisture in, increasing insulation-failure risk.

Loose or damaged tape at HV cable
joints lets moisture in, increasing
insulation-failure risk.

Applications. HV connections and cable joints.

Technology. Self-fusing silicone tape insulates
and weatherproofs. Published range: 600 V-35 kV
and up to +300°C, with specified build-up and
conditions.

Customer gain. Keep joint insulation secure.
Reduce weather-related damage and connection
faults.

05

DIELECTRIC ANTI-CORROSION

Preserve metal assets and reduce electrical leakage risk.

33

1040 TST + 727 SHP - Anti-Corrosion System

Rust on transformer tanks and radiators can progress to oil leaks and expensive outages.

Rust on transformer tanks and
radiators can progress to oil leaks
and expensive outages.

Applications. Transformer tanks, radiators and
steel exposed to corrosion.

Technology. Surface-tolerant epoxy-PU for
difficult-to-prepare steel. 727 SHP topcoat repels
dust and moisture; durable and weather-resistant.

Customer gain. Reduce corrosion-driven oil
leaks and repeat painting. Protect the
transformer from costly damage.

34

#2080 Electrohyb SHP - Hybrid Insulation

An electrical fault can make metal poles or enclosures live, endangering anyone who touches them.

An electrical fault can make metal
poles or enclosures live,
endangering anyone who touches
them.

Applications. Metal lighting poles, panels and
specified bus-bar surfaces.

Technology. World-first SHP dielectric coating:
26.5 kV/mm; specified protection system up to 11
kV. Self-extinguishing and dust- and
water-repellent.

Customer gain. Reduce leakage and accidental
contact risk while preventing corrosion. Use the
specified thickness with the complete electrical
safety system.

Home Download