FIRESTOP.

THE STANVAC STANDARD

A firestop for every opening on your drawing.

Building under construction. Illustrative scene.

Building under construction. Illustrative scene.

Seal the opening. Protect the cable. Defend the panel.

Four fire-protection technologies. One coordinated specification.

32 years of industrial chemistry · 3 manufacturing plants · 41 industries

Trusted by Reliance, Adani, Tata Steel, SAIL and UltraTech.

01

Four technologies. One company.

01
Cementitious firestop mortar

Strong, economical seals for wall and floor openings.

02
Ablative barriers

Clean installation and future cable re-entry.

03
Intumescent cable coatings

Flame-spread control and full-length circuit-survival systems.

04
Fire-retardant panel finishes

Protects the painted surfaces inside electrical panels.

Use the test for the task: IS 12458 for penetration seals; IEC 60332 for cable flame spread; IEC 60331 for circuit survival.

02

What the building standard requires.

NBCS 2026 / SP 7:2026 / PART F - FIRE AND LIFE SAFETY

1.

FM AND UL ARE NOT SPECIFIED.

Clause 3.5.4.4 cites IS 12458:2019 [F(34)] for these penetration seals. FM / UL certificates or ASTM reports alone do not establish IS compliance.

2.

Both tests are required.

Fire test + mandatory hose-stream test. Require both results for the specified seal assembly.

3.

A 2-hour wall needs a 2-hour seal.

At least 120 minutes for applicable cable / conduit openings [3.5.4.4]. Distribution-cable shaft seals at each floor must match the floor rating [3.5.5.1].

4.

Where Part F applies.

Check occupancy, height and area. Examples: education, assembly and storage above 9 m; low / moderate-hazard industry over 2,000 m². Area triggers and shaft exclusions apply.

5.

NBCS 2026 replaces NBC 2016.

SP 7:2026, effective 30 April 2026, provides national guidance. State bye-laws and fire-authority conditions govern acceptance; existing local bye-laws continue until amended.

An unsealed opening defeats a fire-rated wall.

Fire and smoke cross gaps; flames travel along cables. At handover: who specified the seal, and was it tested?

03

The full system range.

THE OPENING / THE CABLE / THE PANEL

A. Seal the opening.

NBCS Part F: 3.5.4.4 (penetrations); 3.5.5.1 (shaft floor seals).

FIREX SYSTEM
WHERE / WHAT YOU GAIN
SEAL / RATING
FM-71
Load-bearing floor and wall openings.
75 mm
Cementitious mortar
Strong, lightweight and economical. Permanent seal.
2 hours
FM-71 + FB-250
Cable routes requiring future changes.
100 mm
Composite system
Mortar strength + a re-enterable barrier. Reinstate after cable changes.
2 hours
50 + 50 mm
FB-250
Occupied buildings, data halls and retrofit.
100 mm
Ablative mineral wool
Fast, clean, dry and re-enterable. No wet mortar work beside equipment.
2 hours

Ratings apply to the tested assembly. Match the substrate, opening, services, seal depth and installation detail.

FM-71 / Mortar floor seal
FB-250 / Wall barrier
FM-71 / Mortar floor seal
FB-250 / Wall barrier

Installation illustrations.

B. Protect the cables passing through.

1 foot of EC 43 at every penetration. Included free.

The seal closes the gap. EC 43 limits flame spread along the cable.

EC 43 General: flame-spread protection tested to 240 minutes / IEC 60332-3 in the tested cable assembly.

Sealed opening + coated cables: two fire paths addressed. Installation illustration.

Sealed opening + coated cables: two fire paths addressed. Installation illustration.

C. Add circuit and panel protection.

OPTIONAL UPGRADES

EC 43 Survival
Critical circuits that must keep working.
Fire-pump, alarm and trip circuits: full-length protection, 240 minutes at 750°C / IEC 60331-21, in the tested system.
NBCS context: Part F, 3.5.5.2 - emergency power. Select the complete system to project requirements.
EC 7034
Thin panel wiring: fire + rodent protection.
Flexible, translucent coating. Protects the small wires that can fuel a panel fire. 120 minutes / IEC 60332-3-22, Cat A.
DC 52
Fire-retardant finish for internal panel paint.
Adds fire protection over the existing painted surface.

Local flame-spread control and full-length circuit survival are separate specifications.

04

4 reasons to specify STANVAC.

1.

Tested to the cited Indian standard.

FIREX systems are tested to IS 12458:2019 at CSIR-CBRI, Roorkee, a Government of India laboratory. Use the relevant assembly report for project approval.

2.

One accountable partner.

Survey, specification paragraph, drawings, method statements and trained applicators - coordinated firestop, cable and panel protection.

3.

Two fire paths protected.

2 hours at the penetration plus cable flame-spread protection tested to 4 hours / 240 minutes. The 1-foot EC 43 coating is included free.

4.

Why pay more for what the clause does not specify?

A lower-cost Indian alternative: IS-tested seal + free cable coating. Compare imported FM / UL offers on the complete installed package: seal, cable treatment, installation and documentation.

05

Indian expertise. Site support.

Indian manufacturing. Tested systems. Site support from survey to installation.

STANVAC / Gurugram facility. Enhanced source photograph.

STANVAC / Gurugram facility. Enhanced source photograph.

PCO / PANELS · CABLES · OPENINGS

Send your drawings. Ask for a site survey and specification.