CABLE + JOINT PROTECTION

Z931B STRIPPEX

SHP INTUMESCENT COATING

CABLE & JOINT FAILURESSTOP PLANTS.

INSULATE. SEAL. LIMIT FIRE SPREAD.

FIVE APPLICATIONS. ONE PROTECTION SYSTEM.

01TAPED CONNECTIONS

SERIOUS FIRE & BREAKDOWN RISK

Tape can open. Faulty joints can arc.
Burning tape can spread fire.

Loose, failing tape on a cable joint lying on a cable tray

BEFORE: LOOSE TAPE

The same cable joint repaired and coated with Z931B

AFTER: REPAIRED & COATED

ENCAPSULATE THE JOINT. LIMIT FIRE SPREAD.

ILLUSTRATIVE COMPARISON

DURING FLAME

931B

UNCOATED

Two vertical cables held over a burner flame: the 931B-coated cable on the left, the taped cable on the right

931B: FORMS INTUMESCENT CHAR

TAPE: FLAMES TRAVEL UP

BURNER OFF

931B

UNCOATED

The same two cables after the burner is switched off: the 931B cable is not flaming, the taped cable is still burning

931B: NO VISIBLE FLAMING

TAPE: STILL BURNING

02CABLE SHEATHS

BEFORE: CRACKED SHEATH

AFTER: LOCAL 931B REPAIR

LOCAL REPAIR CAN AVOID CABLE REPLACEMENT.

Restores protection against water and contamination where inner
insulation is sound.

USE: Fixed power / telecom cables; racks; motor feeds.

03CABLE JOINTS

Cable joint with a failed seal on a cable tray

BEFORE: FAILED JOINT SEAL

The same cable joint after repair and coating

AFTER: REPAIRED & COATED

ADDED INSULATION. WATER-REPELLENT PROTECTION.

Encapsulates sound, correctly repaired and sealed joint exteriors.

USE: In-line / sleeved joints; sleeve-to-sheath transitions.

04BUSBAR JOINTS

Three coloured busbars with corroded copper splice joints

BEFORE: CORRODED SPLICE

The same busbar joints and bolts coated in the phase colours

AFTER: COATED JOINT & BOLTS

INSULATE EXPOSED METAL. RESIST WETTING & CORROSION.

USE: Switchboards; bus ducts; rising mains; bus couplers.

Clean, repair and check torque first.

05LUG JOINTS

Heat-damaged lug joint on a motor terminal

BEFORE: HEAT-DAMAGED JOINT

The same lug, nut and stud repaired and coated in red

AFTER: REPAIRED & COATED

INSULATES THE LUG, NUT & STUD.

USE: Motor / generator terminals; MCCs; transformer LV lugs; UPS / rectifier
DC connections.

HELPS RESIST TERMINAL-SCREW LOOSENING

Cured film helps restrain screw rotation under vibration.

Application illustrations show repaired connections before coating.

ONE SYSTEM. THREE PROTECTION BENEFITS.

UP TO

11 kV

INSULATION TEST
BEFORE FIRE

120 min

IEC 60332
FLAME-SPREAD TEST

CSIR-CBRI

SHP

REPELS DUST
& WATER

FOR HT: USE TOGETHER WITH 955 SL TAPE.

BRUSH-APPLIED. FLEXIBLE. AIR-DRYING. AGEING-RESISTANT.

START WITH CRITICAL CONNECTIONS.

Main incomers. Bus couplers. Critical pump / fan feeds.

PLANTCHECK FIRST
Steel / foundriesFurnace cables; rolling-line terminals
CementKiln / cooler fan feeds; MCCs
PowerBoiler cables; generator terminals
Chemicals / refineriesPump bays; process cable racks
Paper / food / pharmaDryer drives; washdown entries
All plantsOutdoor racks; bus ducts; fixed terminals

ONE COMBO PACK. BASE + TOP COAT.

931B INTUMESCENT
BASE COAT

3 COATS

40-minute intervals
between base coats.

931B
TOP COAT

2 COATS

After the base-coat
sequence.

Follow specified preparation, coating thickness and curing instructions.

FOUR COLOURS

REDYELLOWBLUEBLACK

PROTECT CABLES & JOINTS.

PROTECT PRODUCTION.

ORDER Z931B STRIPPEX

FOR YOUR NEXT SHUTDOWN.