Keeping People Safe. Keeping Plants Running.

GOVERNMENT OF INDIA

MINISTRY OF STEEL

SG/16  |  FIRE SAFETY GUIDELINE

Rev. 00  |  Effective 14 October 2019

Safety Guidelines for Iron & Steel Sector

Integrated steel plant with a blast furnace, stoves and conveyor galleries under a blue sky

STEEL MILLS.

FIRE SAFETY.
PRODUCTION PROTECTED.

Ministry guidance.
Stanvac technology. Your gain.

10 APPLICATIONS  /  PANELS · CABLES · OPENINGS · SUBSTATIONS

01

RODENTS IN CONTROL GEAR

Rat-bitten red, yellow and blue wires in a control panel; AFTER inset: the same wiring coated and the entry gaps sealed

One bitten wire can stop the mill.

SG/16 · 3.3.16(v)

Protect control gear against rodents, reptiles and insects.

STANVAC SOLUTION

EC 7034 + FBS 73

Translucent, flexible cable protection + reopenable entry-gap
sealing. EC 7034: 0 bites in the reported 30-day rodent test.

YOUR GAIN

Reduce bite-related faults. Keep wire colours
visible.

Replace damaged wiring first. Coat sound sheaths; seal suitable gaps. Keep
contacts and vents clear.

02

PANEL CABLE ENTRIES

Open cable entry below an electrical panel; AFTER inset: the cables coated and the entry closed with a hybrid firestop

An open entry gives fire a route into the panel.

SG/16 · 3.3.17(vii, x)

Above 230 V: coat 1 m below entry and 1 m below
terminations inside, where space permits. At 33 kV and
above, add an entry firestop.

STANVAC SOLUTION

EC 43 + FM 71 + FB250 HYBRID COMBO

Intumescent cable coating + a hybrid firestop barrier: mortar
strength and mineral-wool boards for load-bearing safety and
easier cable retrofitting.

YOUR GAIN

Limit fire entering or leaving critical switchgear.

1.6 mm dry-film thickness. Motor terminal boxes excluded; transformer terminal
boxes included.

03

JOINTS + VERTICAL CABLES

Cable joint and vertical cable riser in a steel plant; AFTER inset: the joint and risers coated

Joints and risers can carry fire upwards.

SG/16 · 3.3.17(vii)

Coat 1 m on both sides of joints and the entire exposed
vertical cable length.

STANVAC SOLUTION

EC 43 / 931B STRIPPEX

EC 43 protects cable runs. 931B adds flexible, water-repellent
insulation on suitable repaired joint exteriors; reported
120-minute IEC 60332 test.

YOUR GAIN

Protect vulnerable joints. Limit vertical fire spread.

Repair and test joints first. Specify the complete coating build; 931B alone is not
a universal SG/16 substitute.

04

FIRE-PRONE CABLE ROUTES

Cable trays running through a hot, fire-prone mill area; AFTER inset: the full cable length coated

Cable insulation can carry fire across the mill.

SG/16 · 3.3.17(viii)

Coat the entire cable length passing through a fire-prone
area.

STANVAC SOLUTION

EC 43 GENERAL / SURVIVAL

GENERAL limits flame spread. SURVIVAL protects circuit
continuity on the matching tested cable system. Select the
grade by duty.

YOUR GAIN

Reduce the risk of a local fire becoming a plant
outage.

Full-route protection for survival duty. Coatings complement detection,
suppression and safe cable routing.

05

CABLE OPENINGS + COMPARTMENTS

Unsealed cable opening in a wall; AFTER inset: the opening sealed with mortar and mineral-wool boards

One unsealed gap can defeat a fire compartment.

SG/16 · 3.3.17(iv, v, ix)

Compartmentalise tunnels, seal cable entries and exits, and
firestop cable-vault entries.

STANVAC SOLUTION

FM 71 + FB250 HYBRID COMBO

Combines mortar strength with mineral-wool boards:
load-bearing safety + easier cable retrofitting. Matching
2-hour tested hybrid assembly.

YOUR GAIN

Contain fire and smoke. Retrofit cables more easily.

Match the tested wall, opening, cables and seal depth. Reinstate the seal after
every cable change.

06

DETECTION + RESPONSE CIRCUITS

Fire alarm sounder and detector above a cable tray with a fire in the background; AFTER inset: the cables coated

A fire can damage the cables needed to respond.

SG/16 · 3.3.17(xi, xii)

Provide automatic fire alarms for cable tunnels, vaults and
trestles above 230 V; select suitable detection, including LHS
where appropriate.

STANVAC SOLUTION

EC 43 SURVIVAL

Additional protection for selected alarm, pump and ventilation
feeds. Tested system: 240 min at 750°C, IEC 60331-21.

YOUR GAIN

Help critical response circuits keep working in fire.

Detectors, alarms, power supplies and firefighting remain separate required
systems. Do not coat sensing elements.

07

UNIFORM COATING THICKNESS

Patchily coated cables on a tray; AFTER inset: an even coating on every exposed side

Missed areas leave weak spots in the protection.

SG/16 · 3.3.17(x)

Achieve 1.6 mm dry-film thickness uniformly on all
exposed sides and along the specified length.

STANVAC SOLUTION

EC 43 + APPLICATION CONTROL

Build the coating to specification. Check every accessible side
and verify dry-film thickness using an approved inspection
method.

YOUR GAIN

Turn a paint application into measurable
protection.

Record preparation, coat build, coverage and thickness at handover. Wet-film
thickness is not dry-film thickness.

08

PERIODIC CABLE PROTECTION

Long cable tray run in a tunnel; AFTER inset: a one-metre coated length on the cables

Long cable routes connect separate risk areas.

SG/16 · 3.3.17(ix)

Above 230 V in tunnels/trays: coat 1 m every 30 m. Treat
cables up to 230 V within 2 m of that route too.

STANVAC SOLUTION

EC 43 GENERAL

Survey and mark each required location. Form a continuous
one-metre coated length on the specified cables, at the
required build.

YOUR GAIN

Add targeted flame-spread protection along long
routes.

Inset shows a 1 m coated length. Fire-prone areas need full-length coating;
survival duty needs the complete route.

09

FIRE DOORS + ADJACENT OPENINGS

Fire door with an unsealed cable opening beside it; AFTER inset: the cable penetration sealed

Fire can bypass a door through nearby gaps.

SG/16 · 3.3.17(xiii; iv, v)

Provide fire-rated doors inside cable premises and at
entries/exits; maintain compartmentation and seal cable
openings.

STANVAC SOLUTION

FM 71 + FB250 HYBRID COMBO

Mortar strength + mineral-wool boards provide load-bearing
safety and easier cable retrofitting at cable penetrations.

YOUR GAIN

Preserve the compartment. Simplify cable changes.

The certified door, frame and hardware are separate plant scope. Firestop rating
must suit the approved compartment.

10

TRANSFORMER FIRE SEPARATION

Oil-filled transformer bay with exposed cables in a trench; AFTER inset: the cables coated and the trench openings sealed

Cable routes can carry fire beyond a transformer.

SG/16 · 3.3.16(viii)(a)

For oil-filled installations above 2,000 litres, provide 4-hour
baffle walls in the specified separation situations.

STANVAC SOLUTION

EC 43 + FM 71 + FB250 HYBRID COMBO

Protect cable routes and openings. The hybrid barrier
combines mortar strength and mineral-wool boards for
load-bearing safety and easier cable retrofitting.

YOUR GAIN

Help restrict secondary cable fires and wider
damage.

The engineered 4-hour wall is separate plant scope. A 2-hour seal does not
create a 4-hour wall.

THE TEST MUST MATCH THE PROTECTION YOU NEED.

0 BITES

EC 7034

30-day rodent test
RDSO/SPN/204
120-min flame test at 1.5 mm

240 MIN

EC 43 GENERAL

Flame-spread test
IEC 60332-3
1.6 mm test build

240 MIN

EC 43 SURVIVAL

Circuit survival at 750°C
IEC 60331-21
XLPE 4-core × 70 mm² / 1.6 mm

2 HOURS

FM 71 + FB250
HYBRID COMBO

Hybrid firestop barrier
IS 12458
Match the tested assembly

Performance figures are reported by Stanvac for specific tested systems. Obtain the matching test report and installation detail. IEC 60332 flame-spread
resistance is different from IEC 60331 circuit survival.

START WITH YOUR MOST VULNERABLE AREA.

Send panel, cable-route and opening photos.

Ask Stanvac for a site survey, system specification and offer.

MINISTRY SOURCE SG/16, Rev. 00, effective 14 October 2019, §§3.3.16–3.3.17. Clause summaries are paraphrased.

PRODUCT DETAILS PCO / EC 43 / EC 7034 / FBS 73 · FM 71 + FB250 HYBRID COMBO · 931B STRIPPEX

Selected electrical-fire applications, not a complete plant fire-safety checklist. Stanvac proposals do not imply ministry endorsement or whole-plant compliance. Confirm site
applicability, current requirements and approved system details. AI plant and application illustrations; “after” shows treatment, not proof of a real installation or fire-test
result. Repair or replace defective cables before coating.

STANVAC CHEMICALS (INDIA) LTD.

15 NOVEMBER 2026