Stanvac

ELECTRICAL WHY BUY / 2026

THE STANVAC ELECTRICAL ADVANTAGE

34

BEST IN INDIA

ELECTRICAL
MAINTENANCE
SOLUTIONS

WHY BUY?

THE TECHNOLOGY DIFFERENCE.

YOUR UNIQUE GAIN.

PROTECT CABLE HIGHWAYS. LIMIT FIRE SPREAD THROUGH THE PLANT.

PROTECT CABLE HIGHWAYS.
LIMIT FIRE SPREAD THROUGH THE PLANT.

CHOOSE YOUR MAINTENANCE NEED

SHP = built-in dust & water repellency. Helps reduce the contamination that contributes to leakage,
tracking, arcing and corrosion.

ALSO DELIVERED TURNKEY

ONE VENDOR. ONE WARRANTY. TESTED OUTCOMES.

01

PASSIVE FIRE PROTECTION

Protect panels, cables and openings against the spread of fire.

STANVAC PCO - PANELS. CABLES. OPENINGS.

Defend each link: panel spark → small wire → cable highway → openings.

01

FIREX FBS 73 - Fire Sealant

SEAL PANEL GAPS. HELP PREVENT PANEL FIRES.

SEAL PANEL GAPS.
HELP PREVENT PANEL FIRES.

Applications. Electrical-panel gaps and cable
entries.

Technology. India's first oxygen-limiting panel
sealant. Flexible and re-enterable; tested up to 2
hours to IS 12458 in the specified arrangement.

Customer gain. Seal out dust, moisture and
pests. Help stop small faults becoming larger
panel fires.

02

FIREX DC 52 - Fire-Suppression Paint

HELP CONTAIN PANEL FIRES. CUT DAMAGE AND DOWNTIME.

HELP CONTAIN PANEL FIRES.
CUT DAMAGE AND DOWNTIME.

Applications. Internal painted surfaces of
electrical panels and cabinets.

Technology. India's first intumescent fire-barrier
panel coating. Limits panel paint feeding a fire and
provides a thermal shield.

Customer gain. Help contain fire at source.
Reduce equipment damage and production
downtime.

3A

FIREX EC 43 - Circuit Survival

KEEP CRITICAL CIRCUITS WORKING THROUGH FIRE.

KEEP CRITICAL CIRCUITS
WORKING THROUGH FIRE.

Applications. Critical-circuit cables that must
operate during a fire.

Technology. World-first fire-survival cable
coating. At 1.6 mm on XLPE 4-core 70 mm²: 180
minutes at 950°C (IS 17505-1); 240 minutes plus
15 minutes cooling at 750°C (IEC 60331-21).

Customer gain. Keep tested circuits working
for the certified duration. Add the specified 0.5
mm 7034 topcoat for anti-rodent protection.

3B

FIREX EC 43 - Flame-Propagation Protection

LIMIT CABLE FIRE SPREAD. PROTECT THE REST OF THE PLANT.

LIMIT CABLE FIRE SPREAD.
PROTECT THE REST OF THE PLANT.

Applications. Cable trays and cable highways.

Technology. CBRI-certified, low-smoke coating:
240-minute flame-propagation performance at 1.6
mm to IEC 60332-3. Circuit survival is covered in
3A.

Customer gain. Limit a local cable fire
spreading through the plant. Add the specified
0.5 mm 7034 topcoat on rodent-prone routes.

04

FIREX 7034 - Anti-Rodent Cable Coating

TRANSLUCENT. FLEXIBLE. RESIST RODENT BITES AND FIRE SPREAD.

TRANSLUCENT. FLEXIBLE.
RESIST RODENT BITES
AND FIRE SPREAD.

Applications. Small-diameter power, data and
instrumentation cables, including panel wiring.

Technology. World's first translucent, flexible,
anti-rodent intumescent coating. Tests: 0 bite
marks coated versus 19 uncoated; SAFE to
RDSO/SPN/204 Annexure G; CBRI 120 minutes to
IEC 60332-3-22, Category A.

Customer gain. Resist rodent bites and fire
spread. Keep cable colours visible and wiring
flexible.

05

FIREX FM 71 - Fire-Stop Mortar

SEAL CABLE OPENINGS. LIMIT FIRE AND SMOKE SPREAD.

SEAL CABLE OPENINGS.
LIMIT FIRE AND SMOKE SPREAD.

Applications. Cable openings in walls and floors.

Technology. CSIR-CBRI tested: 2 hours at 75 mm
to IS 12458; published 20-year life. Options: 75
mm FM 71 or a specified 50 mm FM 71 + 50 mm
FB 250 hybrid.

Customer gain. Limit fire and smoke spread
between rooms and floors. A one-foot EC 43
cable coat addresses the fire path along cables.

06

FIREX FB 250 - Mineral-Wool Fire Barrier

CHANGE CABLES EASILY. RESTORE THE FIRE BARRIER.

CHANGE CABLES EASILY.
RESTORE THE FIRE BARRIER.

Applications. Cable penetrations needing future
cable changes.

Technology. Re-enterable mineral-wool barrier:
100 mm / 2 hours to IS 12458 (CSIR-CBRI).
Specified FM 71 + FB 250 + EC 43 hybrids can
extend protection to 4 hours.

Customer gain. Add or change cables and
reinstate the seal. Combine with FM 71 for
load-bearing capability.

02

CLEANING, INSULATION & PROTECTION

Clean, insulate and protect electrical assets for more reliable service.

07

#901 Easy Clean CO₂ 360 SHP NF

CLEAN PANELS ON-LINE. AVOID PRODUCTION SHUTDOWNS.

CLEAN PANELS ON-LINE.
AVOID PRODUCTION SHUTDOWNS.

Applications. On-line panel relays, contactors
and plastic-sensitive surfaces.

Technology. Non-flammable, plastic-compatible
cleaner with CO₂ 360° spray. SHP repels dust and
moisture.

Customer gain. Clean suitable equipment
without a shutdown. Reduce production loss and
contamination-related faults.

08

#415 Off-Line Contact Cleaner CO₂ 360 SHP

CLEAN CONTACTS. FEWER SWITCHING FAULTS.

CLEAN CONTACTS.
FEWER SWITCHING FAULTS.

Applications. Isolated switches, relays and
contactors.

Technology. Plastic-compatible, CFC-free
cleaner. Fast drying; no residue. SHP repels dust
and moisture.

Customer gain. Reduce switching faults and
extend the interval between cleanings.

09

#8376 Electronic Component Cleaner

CLEAN PCBs IN AC ROOMS. LOW ODOUR. NO RESIDUE.

CLEAN PCBs IN AC ROOMS.
LOW ODOUR. NO RESIDUE.

Applications. Sensitive PCBs and electronics in
AC control rooms.

Technology. Low-odour, plastic-compatible,
residue-free cleaner. CO₂ 360° spray; SHP dust
and moisture repellency.

Customer gain. Clean electronics with minimal
odour and no residue. Help prevent
moisture-related tracking and leakage.

10

#8060 Safety Solvent CO₂ 360 NF

REMOVE HEAVY OIL & GREASE. CUT CLEANING DOWNTIME.

REMOVE HEAVY OIL & GREASE.
CUT CLEANING DOWNTIME.

Applications. Heavy oil and grease on electrical
equipment.

Technology. Non-flammable, dielectric cleaner
with CO₂ 360° spray. Removes oil and grease
without residue.

Customer gain. Deep-clean suitable equipment
in place. Reduce dismantling and cleaning
downtime.

11

#8070 Electrical 88 CO₂ SHP

DRIVE OUT MOISTURE. REDUCE MONSOON FLASHOVERS.

DRIVE OUT MOISTURE.
REDUCE MONSOON FLASHOVERS.

Applications. Damp motor windings and bus bars
in humid, coastal and monsoon conditions.

Technology. Heavier-than-water formula
displaces moisture and helps restore insulation
resistance. SHP repels dust and water.

Customer gain. Reduce moisture-related
flashovers. Published protection: up to six
months under specified conditions.

12

#8480 Carbon Cleaner

REMOVE STUBBORN CARBON. PRESERVE COSTLY CONTACTS.

REMOVE STUBBORN CARBON.
PRESERVE COSTLY CONTACTS.

Applications. Flashover carbon on contacts,
commutators and contactors.

Technology. Thick-film foam gel lifts heavy
carbon without abrasives; compatible with
specified silver and copper surfaces.

Customer gain. Clean without scratching.
Extend contact life and reduce replacement.

13

#6084 Red Insulating Varnish SHP - Class F

EXTEND MOTOR LIFE. REDUCE COSTLY REWINDS.

EXTEND MOTOR LIFE.
REDUCE COSTLY REWINDS.

Applications. Motor winding end-turns,
accessible through opened end covers.

Technology. Fast-drying SHP varnish coats
windings in place. Resists arcing and tracking;
repels dust and moisture.

Customer gain. Preserve insulation resistance.
Extend motor life and reduce costly rewinds.

14

#Z906 Provar Anti-Track SHP - Class H

RESIST SURFACE TRACKING. REDUCE PANEL BREAKDOWNS.

RESIST SURFACE TRACKING.
REDUCE PANEL BREAKDOWNS.

Applications. Panel insulators, current
transformers and potential transformers.

Technology. High-dielectric-strength SHP coating
helps restore insulation resistance. Repels dust
and moisture that cause surface tracking.

Customer gain. Reduce flashovers and panel
breakdowns. Keep metering reliable for longer.

15

#1465(A) Flexiguard SHP

RESEAL AGED CABLE JOINTS. EXTEND CABLE LIFE.

RESEAL AGED CABLE JOINTS.
EXTEND CABLE LIFE.

Applications. Cable joints and cracked or aged
cable sheathing.

Technology. Flexible, fire-retardant SHP coating
bonds to specified PVC, rubber and metal. Repels
dust and moisture.

Customer gain. Keep moisture out of damaged
sheathing and joints. Extend cable service life.

16

#Z931(A) Strippex SHP

INSULATE VULNERABLE JOINTS. REDUCE ARCING & OVERHEATING.

INSULATE VULNERABLE JOINTS.
REDUCE ARCING & OVERHEATING.

Applications. Motor-cable, busbar-cable and
assembled bus-bar joints.

Technology. Air-drying rubberised coating seals,
insulates and colour-codes joints. Ratings: 2 kV
aerosol / 11 kV bulk, as specified. SHP repels dust
and water.

Customer gain. Protect connections from
moisture and corrosion. Reduce arcing,
overheating and connection failures.

17

#6004 Kleer Kote SHP

PROTECT COSTLY PCBs. REPEL MOISTURE AND DUST.

PROTECT COSTLY PCBs.
REPEL MOISTURE AND DUST.

Applications. PCBs exposed to dust, moisture
and fumes.

Technology. Transparent, solder-through SHP
coating. Repels dust and water; resists cracking,
peeling and discolouration.

Customer gain. Reduce leakage and corrosion
between tracks. Protect costly boards and
extend electronic life.

18

#6006 Battery Terminal Coating

PREVENT TERMINAL SULPHATION. 12 MONTHS' PROTECTION.

PREVENT TERMINAL SULPHATION.
12 MONTHS' PROTECTION.

Applications. Cleaned battery terminals.

Technology. Airtight, waterproof, acid-resistant
waxy film. Protects without dismantling; published
protection of at least 12 months.

Customer gain. Reduce corrosion and
sulphation. Keep connections reliable and cut
terminal maintenance.

19

#Z911 Corroclean (SP)

CLEAN CORRODED TERMINALS. RESTORE RELIABLE CONNECTIONS.

CLEAN CORRODED TERMINALS.
RESTORE RELIABLE CONNECTIONS.

Applications. Acid deposits and corrosion on
battery terminals.

Technology. Thick foam neutralises acid. Built-in
indicator dye; cleans suitable terminals in place.

Customer gain. Restore cleaner connections
quickly. Help improve battery reliability and life.

20

#Z201 Pufseal (1K-S)

CLOSE CABLE-ENTRY GAPS. KEEP DUST AND PESTS OUT.

CLOSE CABLE-ENTRY GAPS.
KEEP DUST AND PESTS OUT.

Applications. Awkward cable-entry gaps and
voids.

Technology. One-component PU foam
self-expands into gaps. For fire or anti-rodent
protection, use the specified overcoating and
tested system.

Customer gain. Block entry paths for dust,
moisture, insects and rodents. Reduce
equipment contamination.

21

#Z982 Transformer Oil Leakage Repair Kit

STOP TRANSFORMER OIL LEAKS. AVOID A REPAIR SHUTDOWN.

STOP TRANSFORMER OIL LEAKS.
AVOID A REPAIR SHUTDOWN.

Applications. Accessible transformer tank leaks
suitable for external repair.

Technology. Clean, plug and overlay: seal the
leak and reinforce the repair.

Customer gain. Stop oil loss on suitable leaks
without a shutdown. Protect the transformer and
reduce oil wastage.

22

#Z112 Acidifoam

CLEAN COPPER & ALUMINIUM. BETTER ELECTRICAL CONNECTIONS.

CLEAN COPPER & ALUMINIUM.
BETTER ELECTRICAL CONNECTIONS.

Applications. Copper and aluminium bus bars
and compatible metals, during isolated
maintenance.

Technology. High-foam, phosphate-free cleaner
removes deposits from copper, aluminium and
steel.

Customer gain. Restore clean contact surfaces
without abrasive damage. Support reliable
electrical connections.

23

#Z118 EQC-10

REMOVE INSULATOR SCALE. HELP COATINGS BOND AND LAST.

REMOVE INSULATOR SCALE.
HELP COATINGS BOND AND LAST.

Applications. Insulators with hard, cement-like
deposits.

Technology. Fast-acting acid scale remover
prepares compatible surfaces for anti-track
coatings.

Customer gain. Improve coating adhesion and
help anti-track protection last longer.

24

#7007 Cold Galvanizing Compound SHP

RESTORE ZINC PROTECTION. REDUCE REPEAT RUST REPAIRS.

RESTORE ZINC PROTECTION.
REDUCE REPEAT RUST REPAIRS.

Applications. Steel towers, pylons, poles, welds
and damaged galvanised areas.

Technology. 93% zinc provides cathodic
protection. SHP repels rain and dust.

Customer gain. Restore protection at
vulnerable steel areas. Reduce repeat rust
repairs and extend asset life.

25

#8078 DGCS - Dry Graphite Conductive Sealant

KEEP HV CONTACTS COOLER. REDUCE UNPLANNED OUTAGES.

KEEP HV CONTACTS COOLER.
REDUCE UNPLANNED OUTAGES.

Applications. Specified HV contacts, joints and
bus-bar interfaces.

Technology. Dry graphite conductive film limits
bi-metallic corrosion. Non-flammable and
non-flaking.

Customer gain. Reduce arcing, overheating
and jamming. Keep contact interfaces reliable
with fewer unplanned outages.

26

Super 230 - Gas Leak Detection Spray

FIND SF₆ LEAKS FAST. CUT GAS LOSS AND DOWNTIME.

FIND SF₆ LEAKS FAST.
CUT GAS LOSS AND DOWNTIME.

Applications. SF₆ breaker valves and joints, gas
lines and compressed-air systems.

Technology. Non-flammable spray pinpoints
escaping gas at accessible joints and fittings.

Customer gain. Find and repair leaks quickly.
Reduce gas loss, equipment downtime and
operating problems.

27

SL-ECG #2 Electrotherm - Contact Grease

COOLER CONTACTS. BETTER CURRENT FLOW. LESS MAINTENANCE.

COOLER CONTACTS.
BETTER CURRENT FLOW.
LESS MAINTENANCE.

Applications. Current-carrying connections,
contacts and bolted bus-bar interfaces.

Technology. Synthetic contact grease protects
against corrosion and supports effective current
transfer.

Customer gain. Reduce contact overheating
and deterioration. Extend connection life and cut
maintenance.

28

Superquiet 100 - HT Motor Grease

EXTEND BEARING LIFE. KEEP GREASE OUT OF WINDINGS.

EXTEND BEARING LIFE.
KEEP GREASE OUT OF WINDINGS.

Applications. HT motor bearings exposed to heat
and grease migration.

Technology. 100% synthetic, PTFE-fortified
grease resists melting and migration. Published
ratings: 180°C and 3,000 rpm.

Customer gain. Keep grease at the bearing
and out of windings. Extend bearing life and
reduce motor failures.

29

#6030 Pen Oil - Heavy-Duty Penetrant

FREE SEIZED NUTS AND BOLTS. SAVE TIME AND LABOUR.

FREE SEIZED NUTS AND BOLTS.
SAVE TIME AND LABOUR.

Applications. Seized nuts, bolts and rusted
assemblies.

Technology. Heavy-duty penetrant works into
rust-bound interfaces to release stubborn
fasteners.

Customer gain. Free the part with less time
and labour. Reduce damage and replacement
costs.

03

DIELECTRIC FLOOR COATING

Provide specified operator protection with a continuous floor system.

30

1311 Stangard Insulkote - Class A, B & C

PROTECT PANEL OPERATORS. KEEP FLOORS CLEAN & DUST-FREE.

PROTECT PANEL OPERATORS.
KEEP FLOORS CLEAN & DUST-FREE.

Applications. Electrical-panel operating floors.

Technology. Tested to all six IS 15652:2006
requirements. Nano-ceramic fillers improve
scratch resistance; moisture-tolerant primer
improves adhesion. Published life: 10 years.

Customer gain. Provide specified operator
shock protection with a continuous, cleanable
floor. Keep panel rooms cleaner and dust-free.

04

TRANSFORMER & HIGH-VOLTAGE INSULATION

Protect high-voltage connections from flashovers and environmental exposure.

31

HVI 33 KV - High-Voltage Insulation

REDUCE HV FLASHOVERS. KEEP POWER SUPPLY RELIABLE.

REDUCE HV FLASHOVERS.
KEEP POWER SUPPLY RELIABLE.

Applications. HV lines and bus bars exposed to
fog, pollution, animals and kite thread.

Technology. Protective insulation coating
reduces flashovers from contamination and
accidental bridging, within specified system
ratings.

Customer gain. Reduce power outages,
equipment damage and downtime.

32

#Z955 Strippex (SL) - Self-Fusing Tape

WEATHERPROOF HV JOINTS. KEEP INSULATION SECURE.

WEATHERPROOF HV JOINTS.
KEEP INSULATION SECURE.

Applications. HV connections and cable joints.

Technology. Self-fusing silicone tape insulates
and weatherproofs. Published range: 600 V-35 kV
and up to +300°C, with specified build-up and
conditions.

Customer gain. Keep joint insulation secure.
Reduce weather-related damage and connection
faults.

05

DIELECTRIC ANTI-CORROSION

Preserve metal assets and reduce electrical leakage risk.

33

1040 TST + 727 SHP - Anti-Corrosion System

PROTECT TRANSFORMER STEEL. REDUCE RUST AND OIL LEAKS.

PROTECT TRANSFORMER STEEL.
REDUCE RUST AND OIL LEAKS.

Applications. Transformer tanks, radiators and
steel exposed to corrosion.

Technology. Surface-tolerant epoxy-PU for
difficult-to-prepare steel. 727 SHP topcoat repels
dust and moisture; durable and weather-resistant.

Customer gain. Reduce corrosion-driven oil
leaks and repeat painting. Protect the
transformer from costly damage.

34

#2080 Electrohyb SHP - Hybrid Insulation

REDUCE ELECTRIC SHOCK RISK. PROTECT METAL FROM RUST.

REDUCE ELECTRIC SHOCK RISK.
PROTECT METAL FROM RUST.

Applications. Metal lighting poles, panels and
specified bus-bar surfaces.

Technology. World-first SHP dielectric coating:
26.5 kV/mm; specified protection system up to 11
kV. Self-extinguishing and dust- and
water-repellent.

Customer gain. Reduce leakage and accidental
contact risk while preventing corrosion. Use the
specified thickness with the complete electrical
safety system.

Home Download